Appendix, Eneral, Roubleshooting – Chauvet LED 360 User Manual

Page 13: Ppendix, General troubleshooting

Advertising
background image


5. Appendix

13

8/31/2010 4:41 PM

5.

A

PPENDIX

General Troubleshooting

S

YMPTOM

P

OSSIBLE

C

AUSE

(

S

)

P

OSSIBLE

A

CTION

(

S

)

Breaker/Fuse

keeps blowing

Excessive circuit load

Check total load placed on the

electrical circuit.

Short circuit along the power

wires

Check for a short in the electrical

wiring (internal and/or external).

Device does not

power up

No power

Check for power on Mains.

Loose power cord

Check power cord

Fixture is not

responding to DMX

Wrong DMX addressing

Check Control Panel and unit

addressing

Damaged DMX cables

Check DMX cables

Wrong polarity settings on the

controller

Check polarity switch settings on

the controller

Loose DMX cables

Check cable connections

Faulty DMX interface

Replace DMX input

Faulty Main PCB

Replace Main PCB

Loss of signal

Non DMX cables

Use only DMX compatible cables

Bouncing signals

Install terminator as suggested.

Long cable / Low level signal

Install amplifier right after fixture

with strong signal.

Too many fixtures

Install an optically coupled DMX

splitter after unit #32.

Interference from AC wires

Keep DMX cables separated from

power cables or black lights.

If you still have a problem after trying the above solutions, please contact CHAUVET®
Technical Support.

Advertising