Pilz PSEN op Advanced Programming Adapter User Manual

Operating manual

Advertising
background image

PSEN op Advanced Programming Adapter

Ethernet Adapter for PSEN op Advanced series

OPERATING MANUAL

1003071-EN-01


SAVE CONFIGURATION

The Adapter can read out the configuration of a Type 4 light curtain of the
PSEN op Advanced series
. It can be used both as a backup in case an
exchange of damaged light curtains is required, and for transferring a configuration
to other light curtains used in the same way in the application.

Step 1: Backup of the configuration

Connect the adapter to the light curtain that is used as a source (see section
"Connection").

Press the button

until the symbol

is shown on the display. The backup

procedure is completed when the DL-LED lo longer flashes (see Fig. 1).

DL Button

Yellow DL led

3s < t < 1min

3s

7-Seg Display

DL

Fig. 1 Download of a configuration

Step 2: Reading the configuration

Connect the adapter to the light curtain to which the configuration is to be
transferred (see section "Connection").
Important: The existing configuration in the programming adapter can only be
copied into light curtains with the same hardware.

Press the button

until the symbol

is shown on the display. The process

of writing is completed when the UL-LED no longer flashes (Fig. 2).

Yellow UL led

3s < t < 1min

7-Seg Display

3s

UL

Fig. 2 Reading the configuration

After a configuration has been successfully transferred from the adapter to
the light curtain, a configuration report is saved. A maximum of 10 transfer
processes can be performed. When this number is achieved, the user has to
download the reports using the PSENopt Configurator software.

Step 3: Downloading the reports and checking the light

curtain configuration

Connect the adapter to the Ethernet network and the supply (see section
"Stand-alone connection").
Load all the reports saved in the adapter via PSENopt Configurator.

The serial number and the corresponding configuration parameters are saved in a
configuration report of a certain light curtain.

Before starting normal plant operation, it must be checked
whether the configured light curtains work to the purpose
for which they are intended.


Deleting the configuration reports

Before deleting, ensure that the report has been saved. Press the button (>
3s)

until the symbol

is shown on the display. Then all the reports in

the adapter are deleted.

OFFLINE CONFIGURATION

Via PSENopt Configurator you can prepare a light curtain configuration and
transfer it to the PSEN op Advanced Programming Adapter. This allows offline
configurations to be created which can later be copied to the corresponding light
curtains.

Step 1: Create configuration

Connect the supply voltage and the Ethernet connection correspondingly. (see
section "Stand-alone connection"). In

PSENopt Configurator,

select

"Configuration of the safety light curtain" to start the offline configuration.

Select the corresponding light curtains from the catalogue and drag it to the middle
(max. 3 Types can be cascaded). The select the corresponding programming
adapter from the network and continue setting the parameters with "Continue".
Then use "Programming" to save the corresponding configuration into the
programming adapter PSEN op Advanced Programming Adapter.
The adapter now includes the configuration that can be transferred to several light
curtains.

Important: Select the correct article number depending on the light curtain
for which the configuration is to be made.
If the wrong light curtain was selected, you cannot load the configuration.

Step 2: Transfer configuration to a light curtain


Connect the adapter to the light curtain (see section "Connection").

Press the button

until the symbol

is shown on the display.

Once the upload has been completed successful, a corresponding
configuration report is saved in the adapter. A maximum of 10 read
processes can be performed in succession. Then load the configuration
reports via PSENopt Configurator
to perform further read processes.

When the load procedure is complete the configuration remains saved in the
adapter: It can then be read to other light curtains (a new report is created for each
upload).

Step 3: Downloading the reports and checking the safety

light curtain configuration


Connect the adapter to the Ethernet network and the supply (see section
"Stand-alone connection").
Then load all the reports saved in the adapter via PSENopt Configurator.


Each configuration report states the serial number of the safety light curtain, in
which the corresponding configuration was read, and all the configuration
parameters.

Before starting normal plant operation it must be checked
that the configured light curtains work to the purpose for
which they are intended.


ERROR LOG

When PSEN op Advanced Programming Adapter is permanently connected to a
light curtain, an error log is written on the adapter. This can be made via the
Software PSENopt Configurator. Detailed diagnostics of random states is
therefore possible.
It is only possible to record errors via the adapter when the Type4 light curtain was
configured with the software.
An error is written to the log when this error can be recovered via RESET.
The maximum number of logs in the adapter depends on the type of cascading: 7
logs per cascading with 3 light curtains, 11 logs per cascading with 2 light curtains,
23 logs per cascading with 1 light curtain.
When the adapter is offset from one light curtain to the next, or the configuration of
the light curtain changes, the current log is deleted and a new log is created.
Connect the adapter to the Ethernet network and the supply (see section
"Stand-alone connection").
In PSENopt Configurator select "Open log of the safety light curtain" to load and
display the logs saved in the adapter.


The log of the safety system includes:

• A report on the safety system with detailed configuration of the light curtain that

the log refers to.

• One or several logs with detailed information on the errors.


SPECIFIC STATUS DISPLAY

When the adapter is connected to a safety light curtain, detailed information on the
status of the light curtain is shown in the

7 segment display.
Further information on the messages on the user interface see: Chapter
"Diagnostics" in the PSEN op light curtain operating manual.

ERROR MESSAGES

OSSD error

Microcontroller error

Optical system error

EDM error

Restart error

Communication error

BCM Configuration error

ACM configuration error

Muting lamp error

STATUS MESSAGES

Light curtain in ALIGN mode, aligned correctly

Light curtain in ALIGN mode, not aligned

Light curtain in ALIGN mode, last optics not aligned

Light curtain in ALIGN mode, optics not aligned

Light curtain in ALIGN mode, middle beam not aligned

Safety light curtain in interlock, activate RESTART

Advanced configuration via PSENopt Configurator is
running

Muting function active

Safety light curtain process ready for override

Override function active

Wrong wiring on the override

Blanking zones limits not observed.

Blanking function active

Advertising