ONLINE MONITORING AND CONFIGURATION

When the adapter is connected to a safety light curtain and to the network, a direct
connection of PSENopt Configurator to the safety light curtains is possible.
Regarding the correct connection of the adapter to the safety light curtain, see
section "Connection".

Monitoring

In PSENopt Configurator select "Monitor" to monitor a light curtain via an adapter
that is connected to the system.

In the protected field of PSENopt Configurator the user can call up the following
updated information:

• Connected type of cascading

• Status of all light axes

• Alignment level
• OSSD status

• Status of inputs of the light curtain

• Status of outputs of the light curtain

• Operating mode (with detailed information on the errors)
• Status of the adapter


The monitoring function is useful particularly for diagnostics and rectifying
problems of the safety light curtains.

Configuration

In PSENopt Configurator, select "Configuration of the safety light curtain" to start
the online configuration procedure of the connected light curtains.

After selecting the light curtain to be configured, perform configuration steps "1-2-
3" to:
1) be able to enter all the configuration parameters,
2) be able to create a new configuration for the safety light curtain and a report of

the configuration. This report is required for checking the new configuration of
the safety light curtain,

3) be able to monitor the operation of the safety light curtain before and after the

configuration.


Further details on the configuration procedure and the setting of parameters see
operating manual PSENopt and online help PSENopt Configurator.

CONNECTION

Connection in head area of the safety light curtain

(Specific user interface, saving, online monitoring and configuration)

Fig. 3 Connection in head area of the safety light curtain

The adapter is connected via the 18-pin interface at the head side:

• Remove the protective plastic cap at the light curtain.

• Connect the adapter (see Fig. 3).

• Tighten the adapter screws.
• Connect the 12-pin connector to the adapter.

• If a muting configuration is used, connect the 5-pin muting connector to the

adapter.

• When using the connection to the PSENopt Configurator, connect the 4-pin

Ethernet connector.

Keep the end caps installed at all the unused connectors and ensure that

they are fixed.

Connection

Pin (colour)

Muting

Blanking

1 (brown)

24V

24V

2 (blue)

0V

0V

3 (white)

RESET/RESTART

RESET/RESTART

4 (green)

OVERRIDE 1

TOLERANCE

5 (pink)

OSSD2

OSSD2

6 (yellow)

EDM

EDM

7 (black)

MUTING DISABLE

TEACH IN

8 (grey)

OSSD1

OSSD1

9 (red)

OVERRIDE 2

N.C.

10 (violet)

MUTING LAMP

BLANKING LAMP

11 (grey-pink)

OVERRIDE STATUS

N.C.

12 (red-blue)

EARTH

EARTH

1 (

brown

)

24V – Out

Not used - keep the

end caps installed!

2 (

white

)

MUTING2

3 (blue)

0V – Out

4 (

black

)

MUTING1

5 (grey)

N.C.

Ethernetconnection

Use Standard-M12-D-coded Ethernetcable

If the connection is not used, keep the end caps installed.

Connection in the foot area of the safety light curtain

(Specific user interface, saving, online monitoring and configuration)

The adapter can also be connected to the 18-pin connector at the foot area of the
safety light curtain.
• Loosen the end cap from the connector of the light curtain.
• Connect the adapter (see Fig. 4).

• Tighten the adapter screws.

• When using the connection to the PSENopt Configurator, connect the 4-pin

Ethernet connector.

• Keep the end caps installed at all the unused connectors and ensure that they

are fixed.

Fig. 4 Connection in the foot area of the safety light curtain

Connection to a cascaded structure

With cascaded light curtains, the adapter can be connected at the head
section of the master safety light curtain (Fig. 3) or in the foot area of the last
Slave safety light curtain (Fig. 4).

Stand-alone connection of the adapter

(Offline configuration, download of the reports, download of the logs)

• Connect the 12-pin M12 connector to the adapter.

• When using the connection to the PSENopt Configurator, connect the 4-pin

Ethernet connector.

The adapter in stand-alone mode does not conform to the protection type

IP 65.

Fig. 5 Stand-alone connections


TCP/IP CONFIGURATION

The client DHCP of the adapter is enabled by default. To enable a connection for
PSENopt Configurator it is normally enough to connect the connector of the
adapter to the internal network. In case of a connection to a PC that does not
belong to any network, the TCP/IP parameters of the PC's operating system have
to be entered as follows:

IP address: 172.27.101.210.
Net mask: 255.255.0.0

The network configuration of the adapter can be changed after connecting to the
adapter in the menu Device-> Settings.

USER INTERFACE

STATUS

INFORMATION

ETH

Adapter connected to Ethernet

Ethernet connection not available

LINK

Adapter connected to PSENopt Configurator

PSENopt Configurator not connected

UL

No report available in the adapter memory

Loading of configuration to the safety light curtain is
in progress

One or several reports saved in the adapter

DL

No configuration available in the adapter memory

Loading of configuration from safety light curtain is
in progress

Downloaded configuration saved in the adapter
memory - ready for reading

Push for over 1.5 s (

is shown on the display), to

load the configuration saved in the adapter.

Push for over 4 s ( is shown on the display ), to
load the safety reports saved in the adapter.

Push for over 1.5 s (

is shown on the display) to

load the configuration of the safety light curtain into
the adapter.

ERROR MESSAGES PSEN op Advanced Programming

Adapter

Backup error of the safety light curtain configuration.

Restore error of the safety light curtain configuration.
Check that the configuration saved in the adapter is
compatible with the connected PSEN op light curtain.

Configuration backup error of the safety light curtain
during initialisation of the log.

The memory of the adapter is full. Please download the
reports via the software.

Error in the operating parameters. Please contact Pilz
customer services.

Error in the TCP/IP parameters, default reset.

Error in the PSEN op Advanced Programming Adapter
memory, default reset.

Error in a report, default reset.

Error in an error log, default reset.






TECHNICAL DETAILS

ELECTRICAL DATA

Supply

24 V DC ± 20%

Current consumption of the
programming adapter

2.4 W

Max. current that is output

1.7 A

Connection:

M12 12-pin
M12 5-pin (for muting)
M12 ETH 4-pin (for using the
PSENopt Configurator)
18-pin (2x9) connector at
Safety light curtain

Cable length
(for electrical supply):

50 m max.


MECHANICAL AND ENVIRONMENTAL DATA

Operating temperature:

-0…+ 55 °C

Storage temperature:

25…+ 70 ℃

Humidity:

15…95 % (non-condensing)

Protection type:

IP65 (EN 60529)

Vibration:

Width = 0.35 mm
Frequency 10 … 55 Hz
20 sweeps per axis, 1 octave/min.
(EN 60068-2-6)

Max. acceleration:

10 g
(EN 60068-2-29)

Housing material:

NANYA PBT 1400 G3

DOWNLOAD PSENopt Configurator

URL

www.pilz.com/Downloads

Search term

PSENopt Configurator




























Pilz GmbH & Co. KG
Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Tel: +49 711 3409-0 - Fax: +49 711 3409-133
www.pilz.com e-mail:[email protected]

Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®, SafetyEYE®,

SafetyNET p®, the spirit of safety® are registered and protected trademarks of Pilz GmbH & Co. KG in

some countries.

2013-09

Advertising