Electrical, Leg location & suggested floor drain detail, Dimensions capacities – Cleveland Range SEL-40-T1 User Manual

Page 2: Flanged foot detail

Advertising
background image

DPK
(OPTION)

39"

991mm

35"

889mm

(RIM

HEIGHT)

71"

1804mm

75

28 3/4"
731mm

(PAN

SURFACE)

A

H

B

(PAN SURFACE)

41"

1042mm

H C

25 15/16"
(659mm)

3 7/8" (99mm)

C

5 1/4"
(134mm)

(FAUCET

OPEN)

30"

(762mm)

5"

(127mm)

(MANUAL

TILT HANDLE)

D

RECOMMENDED FLOOR

SLOPE 1" (26mm) IN 4' (1220mm)

FLOOR DRAIN

PIPE DRAIN RECOMMENDED
MINIMUM VALVE SIZE PLUS 1" (26mm)

4" (102mm) MINIMUM

6" (153mm) RECOMMENDED

DPK
(OPTION)

LEG LOCATION &

SUGGESTED FLOOR DRAIN DETAIL

MODEL

SEL-30-T1

SEL-40-T1

A

37 7/8"

(963mm)

49 7/8"

(1267mm)

RIGHT:

4" (102mm) (manual tilt)

1" (26mm) (power tilt)

LEFT: 0", REAR: 0"

CLEARANCE

DIMENSIONS

CAPACITIES

B

24 1/2"

(623mm)

36 1/2"

(928mm)

F

18 1/4"

(464mm)

24 1/4"

(616mm)

G

5 3/4"

(146mm)

5 3/4"

(146mm)

H

8"

(204mm)

8"

(204mm)

C

31 3/4"

(807mm)

43 3/4"

(1112mm)

D

12"

(305mm)

18"

(458mm)

In 4 oz. servings. Other sizes may be calculated.

30 gallons / 115 Liters.............960

40 gallons / 150 Liters...........1280

SEL-30-T1

390 LBS. (178 KG.)

SEL-40-T1

410 LBS. (187 KG)

APPROXIMATE
SHIPPING WEIGHTS

9 1/2" (241mm)

(PAN DEPTH)

NOTE: OPTIONAL 2" TD VALVE SHOWN IN GRAY

FOR OPTIONAL 2" TD VALVE

INCREASE FLOOR

DRAIN GRATE SIZE TO

24" x 20" (610mm x 508mm)

FLOOR

DRAIN

GRATE

12" x 20"

(305mm x

508mm)

H C

2 1/4"
(57mm)

7/16"Ø, 3 HOLES
ON

3 1/8" (80mm) B.C.D.

FLANGED FOOT DETAIL

(REAR LEGS ONLY

)

120

°

120

°

4 7/8" (124mm)

9/16" (15mm)

1" (26mm)

(MAXIMUM

ADJUSTMENT

2" (51mm)

38"

966mm

TD 2 OUTLET

42 3/4"

1086mm

TD 2

23"

585mm

SECT.

XII

PAGE

10

0707

Litho in U.S.A.

(NOT TO SCALE)

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., NSF, CGA, CSA, ETL and others.

Volts Ph

Hz

Total Amps

Wire

Watts

Size

SEL-30-T1 (Standard Wattage)

208

1

60

12000

57.7

4

208

3

60

12000

33.3

8

240

1

60

12000

50.0

6

240

3

60

12000

28.9

8

380

1

50

10013

26.3

8

380

3

50

10013

15.2

12

416

1

50

12000

28.8

8

416

3

50

12000

16.7

10

480

1

60

12000

25.0

8

480

3

60

12000

14.4

12

SEL-30-T1 (High Wattage)

208

1

60

16020

77.0

3

208

3

60

16020

44.5

6

240

1

60

16020

66.8

4

240

3

60

16020

38.5

6

380

1

50

13367

35.2

8

380

3

50

13367

20.3

10

416

1

50

16020

38.5

6

416

3

50

16020

22.2

10

480

1

60

16020

33.4

8

480

3

60

16020

19.3

10

Volts Ph

Hz

Total Amps

Wire

Watts

Size

SEL-40-T1 (Standard Wattage)

208

1

60

18000

86.5

2

208

3

60

18000

50.0

6

240

1

60

18000

75.0

3

240

3

60

18000

43.3

6

380

1

50

15019

39.5

6

380

3

50

15019

22.8

10

416

1

50

18000

43.3

6

416

3

50

18000

25.0

8

480

1

60

18000

37.5

6

480

3

60

18000

21.7

10

SEL-40-T1 (High Wattage)

208

3

60

24000

66.6

4

240

3

60

24000

57.7

4

380

3

50

20026

30.4

8

416

3

50

24000

33.3

8

480

3

60

24000

28.9

8

ELECTRICAL

Advertising