PROGRAM MENUS

Guidelines for Pulse Brew:

Filter Pack type coffees characteristically extract better with the A and B pulse setting. Decaffeinated coffees normally extract better with the

B pulse setting. High-Yield coffees typically extract better with the C pulse setting. The A, B or C settings may be satisfactory to go well with

your coffee variety or taste profile. There are two additional settings (D and E) that allow you to manually set the ON time pulses and OFF time

pulses.

If Pulse Brew is selected (ON), Cold Brew Lock is set to within 15ºF of set point and Cold Brew Lock disappears from the list of pro-

gram selections. When Pulse Brew is ON, Pre-infusion disappears from the list of program selections.

Display Brew Time (Factory set to ON). Press  to display ON or OFF. Pressing either < or > toggles between on and off. Press  to set.

When on, this feature will appear when the brew button is pressed. The brew time will count down.

FreshTrac – Glass (Factory set to 30 min) Press  to Select. Press < or > to move to OFF or a range from 10 Min to 120 Min in 1 minute

increments. Press  to set. This feature allows the operator to control when the RED led on the decanter begins to flash.
Drip-Out Mode (Factory set to 2 min) Press  to select. Press > to increase time (to a maximum of 5 minutes) or < to decrease the time and

turn OFF. Time counts up in 5 second increments. Press  to set.

Display Messages (Factory set to ON) Press  to turn ON or OFF. The message displayed is “Rinse Server Before Brewing”. This message

will alternate; two seconds with Rinse Server Before Brewing, then McDONALD’S - READY will appear for six seconds..

Language (Factory set to English) Pressing < or > toggles between English and French. Press  to set.

Model Select (Factory set to ALPHA-3/4/5) Press  to select, < or > to select model. The selections are: ALPHA-1, ALPHA-2, ALPHA-3/4/5,

Airpot Brewer, Thermo-Alpha. Press  to set. When the Model Select feature is changed, all settings are reset to the defaults of the newly

selected model.

Exit Press  to select, exits program mode and returns unit to operation.

Warmer Temperature Control (Factory set to 90%)

Turn on brewer at the control panel ON/OFF button. Warmer button should be OFF (LED off). Press and hold desired WARMER button. Screen

will display current setting in % of power. Press < or > to increase or decrease power to warmer (50% to 100% in 10% increments). Press  to

set.

Tank Temperature Check

Turn on brewer at the control panel ON/OFF button. Press and hold 3 button (see illustration, page 2) for 5 seconds. Water Temperature will

be displayed. The temperature will not display while the unit is in the process of reheating.
NOTE: Alpha 3GT ONLY; when checking tank temperature, first make sure REAR warmer is ON (red LED on) and then press button 3 for 5

seconds to display tank temperature.

Brew Volume – Easy Access

Units can be easily adjusted from the front panel. Written into the software on the Alpha GT UCM, is a feature to access the brew volume with-

out entering the program mode.
On any multi-station Alpha (ALP2/3/4/5/6GT): Press the center Select button 2 (see illustration, page 2) twice, with the second press hold

down the button for around five [5] seconds.
The screen will display

pressing < or > will adjust the brew volume up or down, ± 20 oz, in 1 ounce increments.