Important Screen

Messages

Component Failure

Service Required

1-(800)-000-0000x

Maintenance Required

Service Required

1-(800)-000-0000x

Brew count "Gallons Since Reset" exceeds
programmed Preventative Maintenance period

Lime Scale Warning

Service Required

1-(800)-000-0000x

Scale Starting to Build Up

Water Level Probe

Water level probe resistance above warning
threshold (test value 23k Ohm)

Low Water Flow Warning

Service Required

1-(800)-000-0000x

If the Inlet valve remains on longer than 40
Seconds (during the brew cycle only) and repeats
TWICE during that brew cycle. It shall clear upon
the next brew and if the same low flow exists
again, it will re-appear.

Water Level Error

Service Required

1-(800)-000-0000x

The fill solenoid has either run for more than 10
minutes on the initial tank fill or 1.5 minutes in
normal operation

Sensor Error

Service Required

1-(800)-000-0000x

Break in the temperature thermistor circuit or short

curcuit.

Over Temp. Error

Service Required

1-(800)-000-0000x

The sensor is reading that temperature in the
heating tank has risen above 210ºF, or sensor has
shorted to ground.

Lime Scale Error

Service Required

1-(800)-000-0000x

Probe

Water level probe resistance above error threshold
(test value 180kOhm)

Internal Error 1

Service Required

1-(800)-000-0000x

ERROR MESSAGES - STOPS BREWING

WARNING MESSAGES - ALLOWS BREWING

MESSAGE DISPLAY

ERROR DESCRIPTION

CAUSE

MESSAGE DISPLAY

WARNING DESCRIPTION

CAUSE

A Component has Failed

Maintenance Required

Low Water Flow

Open Sensor

Excess Temperature

Break in the UPM-UCM Communication circuit.

UPM-UCM Communication

Fill run error / Overflow

Current in one of the components is not within normal

range.