Program Menus GEMTS Brewer

Program Menus

Temperature

Energy Save Mode

Brew Count Odom

Global Recipes

Banner Name

Access Code

Service Call

Master Reset

Cold Brew Lock

Brew Count Total

From Program Menus press > display will show the next feature Global Recipes.

Quality Timer

NON-BREW PROGRAMMING

Temperature (Factory set to 200ºF)

Press to Select. Press < or > to move to desired temperature and then to set. Temperature is programmable from

170ºF to 206ºF in 2-degree increments.

Energy Save Mode (Factory set to OFF)

Press to Select, < or > ON, OFF or ON 140ºF , to set. When in ON, unit will automatically shut off 4 hours from last

brew. When feature is OFF, unit does not utilize the energy saving mode.

In the ON 140ºF position, temperature lowers to 140ºF, if unit has not brewed in 4 hours. This feature will save energy by

maintaining a lower temperature in the tank in periods of non-operation.

Brew Count Odom

Press to display total brew cycles. Press EX or Reset.

Quality Timer (Factory set to OFF)

Press to select, press < or > to choose desired setting. Range 20 min – 240 min, in 10 minute increments. The timer

does two things. It turns on and off a red indicator light and turns off the warmer element. The indicator light signals when a

predetermined time has expired. The warmer shuts off 12 hours after the indicator light comes on.

Brew Count Total

Press to Select, Shows total gallons and total brew cycles on the unit. Cannot be reset.

Cold Brew Lock . . . (Factory set to 5º )

Press to select, < or > to select desired setting (CBL 5, 15 or OFF), to set.

The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The

first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of set point for

the Ready to Brew message, however, it will brew at any temperature.

Master Reset

Press to display Are You Sure?

Then < for Yes, > for No. Brewer factory defaults are then reset.

Service Call (Phone number Factory set to 1-800-000-0000 X0000)

Press to display number and change number or < to move place and EX to exit when complete. This number will be

displayed during a Heating system SENSOR ERROR or during a WATER ERROR.

Access Code (Factory set to 1-2-3-4)

Press to display and change these numbers. The number can be set from 1 to 4. The range is from 1111 to 4444. Press

< to move place and EX to exit when complete.

Banner Name (Factory set to CURTIS)

Press to display letters and change letters or < to move place and EX to exit when complete

This feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks dis‑

ables Banner Name. If programmed, Banner Name is displayed every 5 sec. on and off.

Warmers Auto – Off (Factory setting – Disabled)

Press to Select. Press < or > to adjust from 1 hour to 12 hours. This feature advances in 1 hour increments.

GLOBAL RECIPES

Global Recipes (Factory set to Gourmet STD)

Press to select. If selected, press < or > to chose a recipe based on the type of coffee being brewed. Selections are

Gourmet STD, Light Roast, Dark Roast, High Yield, Filter Pack, or Decaf. Press to select the desired recipe.

Warmers Auto-Off