Manual-20 – Rane SR 4 User Manual

Page 20

Advertising
background image

Manual-20

The SR 4 responds with response data based on the commands/arguments it was

sent. The SR 4 limits its response data to 40 characters. In the case of an error, the

response data is: n,"ERROR" where n is an error code defined below:

Hex

ASCII Error Code Meaning

$31

'1'

Sent <devtype> invalid.

$32

'2'

Sent <checksum> did not verify.

$33

'3'

Sent <command/data> parse error.

$34

'4'

Sent <command/data> greater than 40 characters, or

the number of concatenated commands >4.

$35

'5'

Response <command/data> greater than 40 characters.

See the SR 4 Command Set section below for details of valid SR 4 responses.

<CR> A carriage return ($0D) terminates every message.

SR 4 Command Set

This section details the <command/data> portion of a complete RW 485 mes-

sage. The SR 4 supports 10 commands. Below is a table of commands and associ-

ated responses, followed by descriptions.

Configuration Commands

Cmd Arg(s)* Description

Response**

V

Get Firmware, Hardware Version n1,n2,"OK"

N

["ccc…"]

Read/Write Device's Name

"ccc…","OK"

SPL

n1[,n2]

Read/Write Stored Parameter

n,"OK"

Input Commands

ILD

[n1]

Read/Write LED Enable

n1,"OK"

ILK

[n1]

Read/Write Input Lock

n1,"OK"

IQ

Input Query

n1,n2,"OK"

IR

Input Raw

n1,n2,n3,n4,"OK"

IS

n1,n2

Input Suggest

n1,n2,"OK"

ISR

n1,n2

Input Suggest Raw

n1,n2,n3,n4,"OK"

IF

n1,n2

Input Force

"OK"

* [ ] denotes optional Command Argument

** Responses from concatenated commands produce only one "OK"