Manual-22 – Rane SR 4 User Manual

Page 22

Advertising
background image

Manual-22

To write a stored parameter value:

Send: SPL,n1,n2

Where: n1 is the stored parameter index.

n2 is the value to be stored.

Example: SPL,1,0 sets Auto Level parameter to 0, disabling the

Auto

Level

function.

Response: "OK"

Encoder Input Commands

ILD
Read/Write Encoder LED Enable byte

Reads or writes the Encoder LED Enable byte.

To read the LED Enable byte:

Send: ILD

Response: n1,"OK"

Where: n1 is the Encoder LED Enable byte. The range is [0, 1].

Example: 1,"OK" means that the level LED indication is enabled.

To write the LED Enable byte:

Send: ILD,n1

Where: n1 is the Encoder LED Enable byte. The range is [0, 1].

Example: ILD,0 disables LED indication.

Response: "OK"

ILK
Read/Write Software Input Lock

Reads or writes the input encoder software lock byte. The format of the lock byte is

as follows: bit 0 set locks the level (no action when encoder is turned), bit 1 set locks

the selection (no action when the encoder is pushed in and turned), bit 2 set locks the

enter state (no enter command state change when the encoder is pushed and released

without turning). This lock byte is volatile, meaning upon power up of the device the

software lock byte is always cleared to zero.

To read the Software Input Lock byte:

Send: ILK

Response: n1,"OK"

Where: n1 is the Software Input Lock byte. The lock byte range

is [0, 7].

Example: 3,"OK" means that both the level and selection are

locked.

To write the Software Input Lock status:

Send: ILK,n1

Where: n1 is the Software Input Lock byte. The lock byte range

is [0, 7].

Example: ILK,2 locks the selection.

Response: "OK"