Rane TTM 54i User Manual

Page 6

Advertising
background image

Manual-4

POWER

connector. This is not a telephone jack! Connect only the Rane RS 1 power supply included with your TTM 54i.

MASTER OUT

includes two sets of stereo outputs:

• The ¼" TRS jacks provide high current BALanced output, which should be used whenever driving equipment with a balanced

input or running distances greater than about 10 feet (3 meters). Due to the high drive capability and low impedance, never use a

mono ¼" Tip/Sleeve (no ring) cable in this jack; this grounds one side of the balanced output.

• Use the UNBALanced output for shorter runs, such as connecting to a recorder, looping to another mixer, or to other local signal

processing or amplifiers.

EFFECTS jacks are unbalanced mono ¼" Tip/Sleeve. This stereo loop is inserted in the signal path as in section .

• The SEND jacks provide the output to your effects processor.

• The RETURN jacks provide an input for the signal returning from your effects processor.

21

PGM 1

and PGM 2 inputs include both PHONO and LINE input.

• PHONO 1

and PHONO 2 inputs are RIAA compensated inputs with 18 dB per octave, 20 Hz rumble filters.

• LINE 1

and LINE 2 inputs are unbalanced line level inputs with a nominal sensitivity of -10 dBV.

• PHONO/LINE

selection is made as described in .

• PGM 1

inputs are sent to the left side of the Crossfader. (HAMSTER switch out)

• PGM 2

inputs are sent to the right side of the Crossfader. (HAMSTER switch out)

22

PHONO GND

terminals provide an independent ground connect point for two turntables. It is very important that each turn-

table have a very good ground connection to one of these terminals. The thumb screws are not captivated, so use care not to spin

them off and lose them.

Important Note

CHASSIS GROUNDING

If your system exhibits excessive hum or buzzing, there is an incompatibility in the grounding configuration between units some-

where. Here are some things to try:

1. Check that the turntable grounding wires are connected to the PHONO GND posts (

22

).

2. Try combinations of lifting grounds on units that are supplied with ground lift switches or links.

3. If your equipment is in a rack, verify that all chassis are tied to a good earth ground, either through the line cord grounding pin or

the rack screws to another grounded chassis, or tied to the ground screw located just above the POWER jack.

4. This unit’s outboard power supply does not ground the chassis through the line cord. Make sure that this unit is grounded either to

another chassis which is earth grounded, or directly to the grounding screw on an AC outlet cover by means of a wire connected to

a screw on the chassis with a star washer to guarantee proper contact.

Please refer to RaneNote “Sound System Interconnection” (supplied with this manual and available at our web site) for further

information on system grounding.

18

22

23

24

19

20

21

CLASS 2 EQUIPMENT

UNBAL

BAL

SEND

RETURN

ACN001.187.837

MADE IN U.S.A.

RANE CORP.

R

L

R

L

U.S. PATENT PENDING

RETURN

SEND

INPUT

LINE 1

R

L

PHONO 2

LINE 2

R

L

PHONO 1

MASTER OUT

EFFECTS

MIC

PGM 2

PGM 1

EFFECTS

PHONO GND

TTM 54i

750mA

POWER

Advertising