Pedestal Mount Installation Instructions

Copyright 2014 Talk-A-Phone Co. All rights reserved.


Talk-A-Phone Co.

• 7530 North Natchez Avenue • Niles, Illinois 60714-3804

Page 3 of 3

Phone 773.539.1100 • Fax 773.539.1241 • [email protected] • www.talkaphone.com

All prices and specifications are subject to change without notice.

Talk-A-Phone, Talk-A-Lert, Scream Alert and WEBS are registered trademarks of Talk-A-Phone Co.

V.

Pedestal Installation

1. A polycarbonate light cover protects the LED light assembly from the inside. Peel the protective paper

off the light cover and fit it onto the studs inside the pedestal. Slide the LED board over the studs with
the LEDs facing down. The built-in spacers will keep the LEDs from resting on the acrylic window.
Tighten down using the enclosed #6 lock washers and nuts. Be careful not to over-tighten to avoid
cracking the circuit board.

2.

Install one 3/4” nut and one washer on each anchor bolt 2.5” above grade to top of washer. This will
allow for a 1/2" air gap between the foundation and the pedestal, which will allow airflow and prevent
moisture problems. Verify that the nuts are level (0° pitch).

NOTE: To insure proper grounding of all electrical components, the pedestal mount should be
effectively earth grounded from the grounding stud (located across from the lower access panel) with
6 AWG or better insulated, stranded copper wire to the metallic power service raceway (conduit) or an
8' or longer corrosion-resistant ground spike.

After removing the cover plate from the pedestal’s rear access opening, install the pedestal onto the
bolts with the Emergency Phone opening oriented in the desired direction. Install second set of nuts
and washers. Tighten the upper nuts; the bottom set is only for leveling.

3. Wire incoming power to the faceplate light. The LED board operates on 12VDC up to 120VAC and is

not polarity sensitive.

4. Attach the Emergency Phone to the pedestal with six (6) 10-24 oval head tamperproof screws. If you

have a model ETP-PMD Dual Pedestal Mount, use the other six (6) screws to mount your second
faceplate. Connect the phone line coming into the pedestal to the male RJ11 connector coming from
the Emergency Phone. An outdoor rated RJ11 female modular jack on the end of the incoming phone
line is strongly recommended.

5. Re-attach the cover plate over the access opening.


It is the installer's obligation to ensure compliance with all national, regional, and local regulations.