Low sensitivity, Medium sensitivity, High sensitivity – Talkaphone ETP-UPS Back-up Power Supply User Manual

Page 4: 144 vac, 141 vac, 137 vac, The back-ups frequently switches to battery power, Warnings and system faults, F01 - on-battery overload, F02 - on-battery output short

Advertising
background image

Back-UPS® RS Installation and Operation

4

Unit sensitivity

Adjust the sensitivity of the UPS to control when it will switch to battery power; the higher the sensitivity, the more
often the unit will switch to battery power.

1.Ensure the unit is connected to utility power, but is OFF.

2.Press and hold the

P

OWER

button for six seconds. The

L

OAD

C

APACITY

bar will flash on and off, indicating that the

unit is in programming mode.

3.Press

P

OWER

again to rotate through the menu options. Stop at selected sensitivity. The unit will beep to confirm

the selection.

Warnings and System Faults

Warnings

Press

D

ISPLAY

to scroll through the display screens.

System Faults

The unit will display the fault messages. Contact APC Technical Support for additional support.

Low sensitivity

Medium sensitivity

High sensitivity

78-144 Vac

88-141 Vac

88-137 Vac

Input voltage is extremely low or
high. (Not recommended for
computer loads.)

The Back-UPS frequently switches to
battery power.

The connected equipment is
sensitive to voltage fluctuations.

Warning 1

ON LINE overload condition,
indicated by the illuminated ON
LINE icon, and the flashing
overload icon.

Warning 3

In ON LINE mode, and there is a
bad battery, indicated by the
flashing icon.

Warning 2

Backup battery (ON BATT)
overload condition. This is
indicated by the flashing overload
icon.

Warning 4

The battery charge is low, and
the Battery Charge indicator bar
is flashing.

• F01 - On-Battery Overload
• F02 - On-Battery Output Short
• F03 - On-Battery Xcap Overload
• F04 - Clamp Short
• F05 - Charge Fault
• F06 - Relay Welding
• F07 - Temperature
• F08 - Fan Fault
• F09 - Internal Fault