I. Introduction

The WEBS-RETRO-MT is a kit that converts an existing ETP-MT Tower to a WEBS

®

-capable Mass Notification

Unit. This instruction manual assumes that a fully functional ETP-MT Tower has already been installed.

II. Contents

Before beginning installation, make sure you have all the included components. Each kit consists of two
packages. Package #1, labeled WEBS-RETRO-MT contains the painted WEBS

®

retrofit tower top. Package #2,

labeled WEBS-RETRO-KIT contains the following:

QTY Part

Number Description

4 83073

WEBS

®

Loudspeaker

2

24651

Amplifier Mounting Bracket

2

NA Paging

Amplifier

2

NA

2’ Extension wire for WEBS

®

loudspeakers

3

42841

10-24 x 3/4" pan head tamperproof screw

2

42839

3/4"-10 hex nut

8 42840

3/4"

washer

4

42847

10-24 Hex nuts for Amplifier Bracket

III. Installation

(A) Installing the Retrofit Tower Top

1) Unplug the strobe light from the power supply and the emergency phone.

2) Take off the strobe light attached to the top of the tower by unfastening the three 10-24 x 3/4" pan

head tamperproof screws and keep them safely aside.


3) Remove the cap plate of the retrofit tower top and fasten the unit to the top of the tower with the help

of the three 10-24 x 3/4" pan head tamperproof screws provided.


4) Install the four WEBS

®

loudspeakers by locking each down with the retainer bracket starting with the

bottommost speakers first (see Figure 1).


5) Fasten the strobe light to the top of the cap plate of the WEBS

®

Speaker Unit with the three 10-24 x

3/4" pan head tamperproof screws that were kept aside.


6) Pass the speaker and strobe light wiring through the center hole at the bottom of the retrofit top and

down to the bottom of the tower.

7) Close the top of the retrofit tower top with its cap plate and reconnect the strobe light wiring to the

emergency phone and to its power source.