For PBX Loop Start Trunk Configuration, move the TELEPHONE INTERFACE SLIDE switches on the
module to the positions shown in Figure 5 (i.e. LS and TRUNK). The two center conductors of the RJ11
cord are TIP and RING 48VDC and have a specific polarity. Plug one end of the cord into the Loop Start
Trunk of the PBX and the other end into the TRUNK jack on the module.

Figure 5. WEBS-ZPS (without 7-pin DIP switch) for a PBX Loop Start Trunk configuration.

For PBX Ground Start Trunk Configuration, move the TELEPHONE INTERFACE SLIDE switches on
the module to the positions shown in Figure 6 (i.e. GS and TRUNK). The two center conductors of the
RJ11 cord are TIP and RING 48VDC and have a specific polarity. Plug one end of the cord into the
Ground Start Trunk of the PBX and the other end into the TRUNK jack on the module.

Figure 6. WEBS-ZPS (without 7-pin DIP switch) for a PBX Ground Start Trunk configuration.

The second module should have all its SYS ID 4-pin DIP switches set to zero. Connect the 12VDC power
supply to the module. Remove the switch lock and place the PROGRAM/RUN switch on the second
module to the RUN position. Set the TALK BACK 3-pin DIP switch to the OFF position (to the left) for all
the zones. Set the OUTPUT switch to LO PWR position.

Locate the terminals labeled ZONE A and connect them to the WEBS-MT/R tower. Each WEBS-MT/R
tower is allocated to a single zone on the WEBS-ZPS. Zone A will be Zone 1 and can be paged by
following the directions in Section VI of this manual. Zone B will be Zone 2, Zone C will be Zone 3, and
Zone A of the next module will be Zone 4, etc. Follow the same procedure for the remaining zones. Refer
to Figure 7(a) or 7(b), to connect the WEBS-ZPS to the WEBS-MT/R Amplifier (black chassis) or the