3 operation of the rack mount models, Operation of the rack mount models -3 – CANOGA PERKINS Multiplexer 6002 User Manual

Page 15

Advertising
background image

EdgeAccess

®

Universal Chassis System

6002/6003/6004 WWDM Users Manual

3-3

3.3

Operation of the Rack Mount Models

When the 6002/3/4 RM module is installed into the EdgeAccess Universal Chassis System, a
“STA” or status LED on the front panel will illuminate amber. This test signal from the UCS
verifies that a backplane connection was established. A red light indicates a connection error.

When the 6002/3/4 LED illuminates green, the light indicates:

• The module is properly seated in the UCS slot.

• The module is receiving power from the backplane.

• The module is available to be polled by a management device.

The optional Domain Management Module (DMM) is a Management Access Module (MAM).
When the DMM is installed into an active UCS, it is used for module identification and naming
the installed 6002/3/4 models.

Note: Refer to the EdgeAccess UCS DMM Users Manual for additional instructions.

The optional Chassis Interconnect Module (CIM) is a connecting device that links other UCS
units together. Figure 7 shows an installed DMM, CIM, a 6004 model, two 6002 modules, and
other optional EdgeAccess products. The 6003 rack mount module is not shown, but is similar.

Note: Refer to the appropriate Canoga Perkins Users Manual for operating instructions.

DMM (MGR)

6002

6004 DC Power Supply

CIM

6002

AC Power Supply

Figure 7. Rack Mount Module Components