Chapter 5
Troubleshooting and Maintenance

5.1

Troubleshooting Fiber Optic Cables

All optical cables should be connected using a Tx to Rx, or Rx to Tx orientation for correct MUX
and DEMUX signal operation. Proper labeling of each connecting cable is highly recommended.

5.2

Troubleshooting Guide

The 6002/3/4 models are passive, unidirectional WWDMs. The modules provide simultaneous
transmission of two to four optical signals over a composite SMF pair. Keeping all optical
pathways clean and dust free is imperative for trouble-free operation. Refer to Table 1.

Table 1. Troubleshooting Cause and Solution Chart

Symptom

Possible causes

Solution

1. Dirty fiber optic cable

1. Clean all fiber optic cables in the

circuit

2. Bad connection to

equipment

2. Replace fiber optic cable

connection

3. Optical loss budget has

been exceeded

3. Check loss budget of equipment

being installed

4. Fiber optic cable cut

4. Check the condition and

integrity of all fiber optic cables
in the circuit. Immediately
replace or repair cut fiber optic
cable.

5. Fiber optic cables crossed

5. Reconfigure the link using the

Rx to Tx orientation

Local or remote
equipment is not
receiving optical
signal

6. Local or remote equipment

not transmitting sufficient
optical signal

6. Measure the optical transmit

power of equipment using an
optical power meter. Determine
that the equipment is providing a
sufficient optical signal.