Features, Specifi cations, Caution – Beckett 7556 12V GeniSys Control User Manual

Page 2: Warning, Electrical ratings, Notice, Environmental ratings

Advertising
background image

2

Table 1 - Model Guide

Beckett

GeniSys

12V Control

Part No.

Lockout

Time

Valve-on

delay

time

1

Motor-

off

delay

time

1

7556A 0000

1

15 sec

0 sec

0 sec

7556P 1530

1

15 sec

15 sec

30 sec

7556P 151M

1

15 sec

15 sec

1 min

7556P 152M

1

15 sec

15 sec

2 min

7556P 158M

1

15 sec

15 sec

8 min

1 - Valve-on delay and motor-off delay timings on all models are
programmable with the Beckett Contractor Tool. Other factory
set timings are available. Contact Beckett for alternate timings.

Features

Welded Relay Protection
Limited Relight
Valve-On Delay / Motor-Off Delay (Field
programmable with Beckett’s Contractor
Tool)
15 Second Lockout Time
Interrupted Ignition
Communication Port
Lockout Alarm Output






Specifi cations

Electrical Ratings

Inputs:

Voltage: 12 Vdc nominal (11 to 16 Vdc)
Current: 160 mA nominal (500 mA max at
16 Vdc)*
Enable Load: 40mA at 12 Vdc

Outputs:

Motor: 12 Vdc, 20 full load amps (FLA), 100
locked rotor amps (LRA)
Igniter: 12 Vdc, 5 A
Solenoid Valve: 12 Vdc, 2 A
Lockout Alarm: 12 Vdc, 2A




Do Not Use This
Control Above 5.5 GPH

CAUTION

The 7556 control
draws 60-75mA in the

standby state. If the red control wire is left
powered without a battery charging system,
it can drain a standard 45 Amp hour
automotive battery in two to four weeks.

NOTICE

*

Maintain Specifi ed
Voltage

A low or erratic power supply could result

in impaired burner operation, severe

delayed ignition or an explosion inside the

heat exchanger resulting in a burn and/or

asphyxiation hazard.

Beckett DC Burners require a continuous

supply of 11 to 16 volts DC (at 15 amps for

Model ADC or 25 amps for Model SDC),

measured at the burner during operation.
Consult other DC burner manufacturers’

specifi cations for the correct voltage range.
Special Note: The 7556 Control shuts the

burner down if the input voltage drops to

a sustained level of 10 volts DC, or below.

Operation resumes at a sustained input

voltage of 11 volts DC, or above.
An automotive or small engine charging

system that is capable of supplying the

required continuous voltage/amperage is

recommended with certain road equipment,

such as asphalt hot patchers and similar

applications.
This is especially true while maintaining

nominal load temperatures during idle periods.

WARNING

Do Not Use This
Control in an

Application that is Not Within the Ratings
Listed in This Section. Improper Control
Operation May Result.

CAUTION

Environmental Ratings:

Storage and Operating Ambient
Temperature: -40°F to +160°F (-40°C to
+71°C)
Moisture: 5 to 95% RH, condensing