Chapter 2 Installation and Setup

Setup

23

2.1.3.1 Carrier Detect (CD) Signal Options

There are two switches on the internal switch block which control the response of the CD signal
on the Standard Data Interfaces. These switches operate as a pair and only one switch should be
set to ON at any time.

Factory settings:

CD/DCD set to OFF

CD/SYNC set to ON

The CD signal can be used as an output for an end-to-end Control Channel by setting the CD/
DCD switch to ON and the CD/SYNC switch to OFF. This setting is used only with Standard Data
Interfaces that do not support the expanded interface connector on MC1 and MC2.

The factory setting causes the standard data connector CD signal to track the state of the
modem’s optical receive synchronizer. CD will assert when the modem is in local sync. This also
means that CD will track the state of the front panel Local Sync LED.

On expanded data interfaces, the standard data connector CD signal in the CD = local sync
mode (factory setting) can be used to gate CTS (or its equivalent signal) OFF when the modem’s
receiver is out of sync. See Figure 2-2 for an illustration of this factory setting.

Refer to the sections on the RS-449/422, RS-530, V.35, MC1 and MC2 interfaces for more
information about the CD-CTS gating function.

Figure 2-2 Factory Setting for CD/DCD or CD/SYNC Switches

CD/DCD
(DCD = RTS from
far end)
or CD/SYNC
selector switches

Optical
Receiver

Rx Fiber

Front Panel LED

J2

J3

To
Interfaces

J2 = Standard data
connector

J3 = Expanded data
connector

RTS from far end

Local Sync

CD