Set up snmp access, Manage traps and alarms – CANOGA PERKINS 2345 T3 Fiber Optic Modem User Manual

Page 22

Advertising
background image

EdgeAccess Universal Chassis System

Model 2345 User Manual

3-6

Set Up SNMP Access

Direct SNMP access is available for standalone modems only. To set values for basic system
parameters, including some SNMP parameters, go to the SNMP Configuration Parameters menu. See
Table 6. To access the SNMP Configuration Parameters menu, follow these steps:

1. At the System Configuration menu, type 5, "SNMP Configuration," and press <Enter>. The

SNMP Configuration Parameters screen appears.

2. At the prompt, type an item number and follow the prompts on the screen. Table 6 lists options

for each menu item.

3. To return to the System Configuration menu, press <Esc>.

Table 6. SNMP Configuration Options

Menu Item

Description

1. System Contact
2. System Name
3. System Location

Optional information, up to 50 characters

4. Read Community

Password for SNMP Read access, up to 50 characters, default is
"public"

5. Write Community

Password for SNMP Write access, up to 50 characters, default is
"private"

6. Serial Port Configuration Type of serial port connection: VT100, SLIP, or PPP

7. SLIP/PPP IP Address

IP address for access through Serial Line Internet Protocol (SLIP)
or Point-to-Point Protocol (PPP)

8. Host Table

Opens Host Table screen

Manage Traps and Alarms

Traps are messages that require management attention and are routed to the Network Manager, but do
not trigger alarms. Conditions that generate an alarm require immediate attention. Enable or disable
traps on the Trap Configuration screen and enable or disable alarms on the Alarm Output
Configuration screen.

Use the Trap Configuration screen to view the current configuration and to enable or disable traps for
the 2345. For a list of events that trigger traps, see Table 7. To set up the traps, follow these steps:

1. At the System Configuration menu, type 3, "Trap Configuration," and press <Enter>.

2. At the Trap Configuration screen, type the number for a trap and press <Enter>. See Table 7.

3. Press <Space> to cycle to Enabled or Disabled and press <Enter>.

4. To return to the System Configuration menu, press <Esc>.

These selections do not affect how the Major and Minor LEDs on the CIM report alarms.