EdgeAccess Universal Chassis System

Alarms are configured via the System Configuration Menu. This menu allows the operator to
specify Major / Minor / Off settings for each alarm condition. To set Modem Alarms:

1. From the Main Menu, type "1" and press Enter, to open the System Configuration screen.

2. Type "4" to open the Alarm Output Configuration screen.

3. The Alarm Output Configuration screen appears. There are nine configurable alarm states,

listed by number (See Table 4).

4. To configure a particular alarm, begin by typing its number in the list and pressing Enter.

5. Use the space bar to toggle through alarm choices: Major, Minor, or Off.

6. Press Enter to confirm the alarm configuration choice.

Figure 28. The Alarm Output Configuration Screen

4.4.4 Alarm Functions and Default Settings

The table below describes each alarm's function and its factory default setting.

Table 4: Alarm Output Configuration Option Definition

Alarm Name

Function

Default

Factory

Setting

1 Active Composite Link Alarm Enables or disables alarms 2 through 9

Major

2 Electrical LOS

Loss of signal received from attached equipment Major

3 Electrical AIS Alarm

"All 1's" signal pattern received from attached
equipment

Minor

4 Configuration Alarm

Incompatibility between local and remote
modem, or between main modem module and
the LIMs attached to it

OFF

5 Power Supply Alarm

Failure of power supply in the remote chassis

Minor

6 Test Alarm

Failure of Bit Error Rate Test (BERT) or failure
in the continuous self-test operation

OFF

7 Link Self Test Alarm

Failure of fiber between Local and Remote units Minor

8 Power On Self Test Alarm

Failure of Power-On self-test

Major

9 Inactive Composite Link
Alarm

In a redundant configuration, failure of the
redundant or inactive link

Minor

2461 Modem User Manual

4-9