EdgeAccess Universal Chassis System

2461 Modem User Manual

5-7

5.4.5 Local Bi-Directional Loopback

When activated, the Local Bi-Directional Loopback test will cause all data transmission from the
local user device to be looped back toward the receive side of that same device. At the same time,
all data transmissions from the remote unit will be looped back towards the transmit side of the
same device (Figure 38).

Figure 38. Local Bi-Directional Loopback

5.4.6 Remote Bi-Directional Loopback

When activated, the Remote Bi-Directional Loopback test will cause all data transmission from
the local user device to be looped back after the data Decoder/Encoder functional block in the
remote modem. At the same time, the data transmissions from the remote user device will be
looped back towards the transmit side of the remote user (See Figure 39).

Figure 39. Remote Bi-Directional Loopback