The Model 1040 standalone enclosure, shown in Figure 1, supports one 5U-sized managed module.

Figure 1. Model 1040 Standalone Enclosure

The front provides two switches, five LEDs, one connector, and a slot for a module. The back
includes an AC power cord socket and the ALM IN and ALM OUT connectors.

Switch Setting

Selects

F1/NRM/F2 for the module

F1

Function 1, such as Local loopback

NRM

Normal operation; set this for most applications

F2

Function 2, such as Remote loopback

HDX/FDX for 10BASE-T port

HDX

Half duplex

FDX

Full

duplex

Note: If the link partner is set to auto-negotiation, the link uses 10M and follows the HDX/FDX

switch setting for this port; otherwise, set this switch to match the other switch on the link.

LED State

Definition

PWR Off

No

power

Green

Power is on

ALARM, MAJ and MIN

Off

Normal

MIN

Amber

Minor

alarm

MAJ

Red

Major

alarm

Tx for 10BASE-T port

Off

No transmission

Green blinking

Transmission activity

LNK/Rx for 10BASE-T port

Off

No link

Green

Link is established at full duplex

Amber

Link is established at half duplex

Blinking

Data is received

Note: To clear a latched Minor or Major alarm, push the ACK button.

Connector Provides

ALM IN and ALM OUT, MIN and MAJ

Alarm status from another device (IN) and to
another device (OUT)

10BASE-T

Half or full duplex Ethernet