EdgeAccess Model 1040

4

Installing and Using the 1040 Enclosure

To use the 1040 enclosure, see Figure 1 and follow these steps:

1. Place it on a secure surface with room for air flow and within 7 ft. (2.134 m) of the AC power

source.

2. Insert a module in the guide rails and press it firmly into the backplane, then secure the

thumbscrews finger-tight.

3. At ALM OUT, on the rear panel, connect devices to receive alarm information; see Figure 2.

• NO The contacts are open for normal operation and closed in a fault condition
• COM The electrical common
• NC The contacts are closed for normal operation and open in a fault condition

4. At ALM IN, on the rear panel, connect devices to supply alarm information; see Figure 2.

Connect cabling from the + output on the device to IN+ on the 1040 and from the - output to IN-
on the 1040; the internal alarm sense circuit is optically protected. Connect an optional Frame or
Chassis Ground to FGND.

Figure 2. Model 1040 Alarm Connectors

5. Plug the power cord into the rear of the 1040 enclosure, then plug it into the AC power source;

this turns on the power. To turn off the power, unplug the power cord.

6. To set any switches on the module, install the module in the 1040 enclosure, connect all cables,

and access the module, see the User Manual for the module.

Specifications

Dimensions:

11.70"L x 12.0"W x 1.718"H (297 mm x 305 mm x 44 mm)

Weight:

5.6 lbs (2.5 kg)

Power:

115 to 230 VAC; 50 to 60 Hz autoranging, 14 W maximum

Operating Environment: 0

° to +50°C, Up to 90% humidity (Non-condensing)

Regulatory Compliance

• ETL, cETL (UL 60950 CAN/CSA C22.2 No. 60950, EN/IEC 60950) EN 60825-1, -2
• FCC Part 15B/IC-003/VCCI Class A, C-Tick (AS/NZS 3548)
• EN 55022 Class A, EN 61000-3-2, EN 61000-3-3
• EN 55024
• CE Mark