CANOGA PERKINS L351 ESU User Manual

Page 5

Advertising
background image

Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008

Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com

P/N 6942580 Rev A

Page 5 of 8

Assign an icon and a name for the session.

Figure 8. Connection Properties


After a name and icon is assigned, the COM port properties menu will appear. Configure the
connection settings to the values listed:

• Bits per second: 19200bps
• Data bits: 8

• Parity: None
• Stop bits: 1
• Flow control: None

• Terminal emulation: VT100


If the HyperTerminal screen is scrolling up, make sure that “Terminal Emulation” in the
Properties menu is set to VT100. If the screen shows random symbols instead of letters, verify
that the terminal speed is set to 19200bps.

In the log-in screen, type the default Username “admin” and the Password “admin” to access the
user interface. The MAIN MENU will appear and will allow you to make necessary
configuration changes based on your selection. Refer to the user manual for more detailed
information.

Advertising