Wiring overview – Dynon Avionics Servo Datasheet / Generic Servo Kit (Push-Pull) User Manual

Page 5

Advertising
background image

DYNON AVIONICS

Servo Mounting Instructions – Generic Push-Pull Kit

4

101046-000 Rev E

Wiring Overview

The following diagram provides an overview of the autopilot-specific wiring installation. For the
complete set of wiring and configuration instructions, please see the latest Installation Guide for

your Dynon EFIS product. For a SkyView system please reference the Autopilot Servo
Installation, Configuration, and Calibration
chapter of your SkyView System Installation guide.

For EFIS-D10A, EFIS-D100 or FlightDEK-D180 please reference the Autopilot Installation and
Configuration
chapter of each respective Installation Guide.

Red

Black

Green

Blue

Yellow

Wht/Grn

Wht/Blu

Servo 1

Wires

Pilot-accessible

Servo Power

Switch/Breaker

Aircraft GND

Red

Black

Green

Blue

Yellow

Wht/Grn

Wht/Blu

Servo 2

Wires

Aircraft GND

Aircraft Power (10-30V)

Pitch and Roll Servos

are wired identically, and can

share wiring for convenience at

any point along the run.

5 kohm

Optional resistor for

detecting broken

disengage lines

Pilot-accessible

Disengage/CWS button

(Normally open, momentary)

Usually mounted to the stick

Power (10-30V)

Ground

SkyView Network 1 A or DSAB A

SkyView Network 1 B or DSAB B

Disengage

SkyView Network Data 2 A *

SkyView Network Data 2 B *

Power (10-30V)

Ground

SkyView Network 1 A or DSAB A

SkyView Network 1 B or DSAB B

Disengage

SkyView Network Data 2 A *

SkyView Network Data 2 B *

Servo Current Draw at 12V
(halve the current values for 24V systems)

SV32
Powered but disengaged: 0.1 amps
Engaged and holding, 100% torque: 0.80 amps
Engaged and moving, 100% torque: 1.33 amps

SV42
Powered but disengaged: 0.1 amps
Engaged and holding, 100% torque: 1.11 amps
Engaged and moving, 100% torque: 2.03 amps

SV52
Powered but disengaged: 0.1 amps
Engaged and holding, 100% torque: 1.52 amps
Engaged and moving, 100% torque: 2.80 amps

Aircraft GND

Use 22 AWG wire for SkyNet

and Disengage signals.

Use appropriate wire gauge for

servo power based on current

consumption and length of wire run

Green

Blue

Twisted Pair

Twisted Pair

Twisted Pair

D10A/D100/D180

D25

CONNECTOR

SKYVIEW

D9

CONNECTOR

N/A
N/A

5
4

4
8
6
1

WHT/BLU

WHT/GRN

BLU

GRN

Wht/Grn

Wht/Blu

*NOT USED FOR D10A/D100/D180

Advertising