4 MPLS L2VPN troubleshooting

4.3.11 VC is down though AC is up

Fault symptom

After the configuration of Layer 2 VC, the AC is Up. However, the ping of the peer fails. After
using the

display mpls l2vc

command, you will find the status of the VC is Down and all the

remote VC label and the remote VC MTU are zeros, which are invalid.

[PE] display mpls l2vc

Total ldp vc : 1

0 up

1 down

Client Interface

Atm5/0/0

Session State

up

AC Status

up

VC State

down

VC ID

100

VC Type

ppp

Destination

3.3.3.3

Local VC Label

119809

Remote VC Label

0

Control Word

Disable

Local VC MTU

1500

Remote VC MTU

0

Tunnel Policy Name

--

Traffic Behavior Name

--

PW Template Name

--

Create time

0 days,

0 hours,

20 minutes

UP time

0 days,

0 hours,

0 minutes,

Last change time

0 days,

0 hours,

4 minutes,

Fault analysis

Possible causes are:

The encapsulation types on two ends are different.

The peer is not configured with VC.

Troubleshooting procedure

Step 1 Check that the correct peer addresses are configured on PEs of two ends.

Step 2 Check that the VC IDs on two ends are consistent.

Step 3 Check that the encapsulation types on two ends are consistent.

Step 4 Check that the local VC MTU and the remote VC MTU are consistent.

Step 5 Check that the control word is enabled or disabled on both ends.

—End

Summary

VC uses LDP as the signaling. The negotiation of following parameters is required:

• VC type