REPLACING THE DRIVE BELT

A

WARNING

Personal Injury Hazard.

Be careful when removing agitator brush assembly. The belt tension is high.
Failure to do so could result in personal injury from agitator brush assembly

releasing quickly and snapping away.

Unplug and turn the unit over. Remove the lower

plate as described in the Removing/lnstalling the

Lower Plate section. Remove the agitator brush

assembly (carefully lift it out), and remove the worn
or broken belt from the agitator pulley and motor
drive shaft.

Loop the new belt around the motor drive shaft and

then loop it around the agitator pulley. Use only a

Panasonic Type UB drive belt.

Before reinserting the agitator brush assembly make

sure that the end caps are on correctly. (See the

illustration in the Replacing the Agitator
Assembly section.)

End Cap

Reinstall Agitator

After checking the end caps, reinstall the agitator brush assembly back into the housing grooves.
After installing the agitator brush assembly, hjm it by hand making sure that the belt is not twisted

and all rotating parts turn freely. Replace the lower plate as described in the Removing/lnstalling
the Lower Plate section.

CLEANING THE AGITATOR ASSEMBLY

Switch off the vacuum cleaner and unplug the power

cord before cleaning the agitator assembly. In order
to keep the cleaning efficiency high, clean the agitator
assembly regularly. Remove the lower plate if necessary.

See the Removí n^lnstal ling the Lower Plate section

for the proper procedure.

Agitator assembly - Cut off any carpet pile and

lint entangled around the agitator assembly with

a pair of scissors as illustrated.