Digital intro scan function – Panasonic NV-D48 Series User Manual

Page 25

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

DIGITAL INTRO SCAN FUNCTION

The Intro Scan function plays back the first 10 seconds of

each programme (marked by an index signal) on a tape one
after another on the full screen. The first picture of each of
these 10-second segments is then frozen and displayed as
a still-picture in the 3-Screen Multi Select mode on the right
side of the TV screen from the top to the bottom.

o

e

0

Insert a video cassette on which index signals are
recorded.

Put the VTR in the stop mode or the still playback
mode.

Press the Intro Scan Button.

(The blank three small pictures will appear on the right

of the screen, “S” mark will light up in the Multi-

Function Display, and the Digital Intro Scan will start.)

When the desired scene is reached, press the Play

Button.

•If you want to use the Digital Function after that, press

the Memory/Search Button (the “S” Mark will dis­

appear).

Digital Intro Scan Operation on the VTR

(T) Insert a video cassette.

(Put the VTR in the stop mode.)

Press the Memory/Search Button twice.
(The blank three small picture appears on the right of

the screen and “S” mark appears.)

Press the Fast Forward ►►/Cue © Button.
(The Intro Scan starts.)

(2) When the desired scene is reached, press the Play

Button.
•If you want to use the Digital Function after that, press

the Memory/Search Button (the “S ’ Mark will dis­
appear).

•The Intro Scan function may not be activated for the

first programme recorded close to the beginning of
the tape.

•During the Intro Scan, if there is a portion without

any recording on the tape, the Intro Scan function

will be activated at that position to play back the
tape for about 10 seconds, and the intro Scan will
then continue.

•The Intro Scan function may not be activated, if the

interval between programme starts is less than 2

minutes.

•If a portion without any recording on the tape

continues for more than about 50 minutes, the Intro
Scan function will be cancelled and the playback will
start.

r

•During the Digital Intro Scan, if there is no input

signal (from line input or tuner), the VTR will
automatically be in same condition as the Test
Signal Switch is “ON”
and the small pictures
will be in black-and-
white.

25