Dip switch settings, Transmit mode dip switch settings – Steffes Transceiver User Manual

Page 17

Advertising
background image

14

DIP SWITCH SETTINGS

Factory Defaults

DIP Switch #

Setting

1

ON

2

ON

3

ON

4

OFF

5

OFF

6

OFF

7

OFF

8

OFF

TRANSMIT MODE DIP SWITCH SETTINGS

DIP Switch #1 – Invert Peak

The transceiver receives a signal, (i.e. switch closure), related to on-peak or off-peak from the power
company or other signaling device. The signal may be a switch “open-to-charge” or “close-to-charge”
signal. The transceiver must be set to match the signaling device. If unsure whether or not the signaling
device opens or closes for charging, contact the power company.

ON = Close to Charge (Off-peak), Open for Control (Peak)
OFF = Open for Charge (Off-peak), Close for Control (Peak)

DIP Switches #2, 3, 4, 5 – Channel Selection

DIP switches 2, 3, 4, and 5 are used to select the channel on which the transceiver will transmit (send
signal). There are 15 channels available. Only one transceiver is required per distribution transformer. If
multiple transceivers in the transmit mode are installed on a single distribution transformer, they must
be set to different channels. Select a channel and set DIP switches 2-5 according to the chart below:

Channel

DIP

Switch 2

DIP Switch

3

DIP

Switch 4

DIP

Switch 5

Channel

Speed*

Transmit

Option**

1

On

Off

Off

Off

Slow

Constant

2

Off

On

Off

Off

Slow

Intermittent

3

On

On

Off

Off

Fast

Constant

4

Off

Off

On

Off

Fast

Constant

5

On

Off

On

Off

Fast

Constant

6

Off

On

On

Off

Fast

Intermittent

7

On

On

On

Off

Fast

Constant

8

Off

Off

Off

On

Fast

Intermittent

9

On

Off

Off

On

Fast

Constant

10

Off

On

Off

On

Fast

Constant

11

On

On

Off

On

Fast

Constant

12

Off

Off

On

On

Slow

Constant

13

On

Off

On

On

Slow

Constant

14

Off

On

On

On

Slow

Constant

15

On

On

On

On

Slow

Constant

*

Steffes 1000 and 2000 Series room heating units receive only on “slow” speed channels (Channels 1 or 2 as set
from the factory or on channels 12/13 or 14/15 with a software upgrade). Slow channels transmit a signal every 3-
4 minutes, so can take up to 7-10 minutes for a receiver to receive. Fast channels transmit every minute, so it
generally only takes 2-3 minutes to receive.

**

The Steffes transceiver transmits a signal over the power lines constantly unless set to one of the intermittent
transmit channels shown above. If the power company’s control device is power line carrier (PLC) such as those
manufactured by Cooper Power System/Cannon Technologies, the transceiver must transmit intermittently to
allow the power company’s control device to operate properly. When set to transmit intermittently, the Steffes
Heating systems will display a lower-than-normal percentage of good packets received.

Advertising