Ccrp circuit board configuration diagram – Steffes Comfort Control Relay Panel (CCRP) User Manual

Page 6

Advertising
background image

Comfort Control Relay Panel (CCRP)

Page 3

CCRP

CIRCUIT BOARD CONFIGURATION DIAGRAM

(Refer to Notes on Pages 4 and 5 in this manual)

For operational information on the green LED lights, see Note 2.

If NOT utilizing the automatic charge control feature of the CCRP, a 4300 ohm resistor
must be placed between the two OS terminals to prevent the 2100, 3100, 4100, or 5100
Series heating system(s) from displaying Error 6 (Er 06).

The 4-pole CCRP is configured to utilize relays 1, 2, 3, and 7.

Relay

2

Re
la

y

1

Re
la

y

3

Relay 4

1 2 3

Dip Switches

On

Off

(Refer to Dip Switch Settings in
this manual.) Note direction of dip
switch for "ON" position versus
"OFF" position. Dip Switch 2 and
3 are "ON" in this diagram.

Tran

sformer

Mi
crop

rocessor

Sof

tware

Relay 6

Relay 5

On

LED 3

(See Note 6)

LED 4

Rel

ay

8

LED 2

Re
la

y

9

(See Note 6)

Override Jumper (J8)

LED 5

1 2 3

1 2 3

Relay 7

LED 6

Override Jumper (J9)

Off

1 2 3

N

L2

L1

A1

P2

(See Note 3)

A - Anticipated Peak (See Note 7)

OV1 - Relay #1 Override/Multiple Control Input

OV2 - Relay #2 Override/Multiple Control Input

OV3 - Relay #3 Override/Multiple Control Input

OVC - Override Common

C - Low Voltage Common

Terminal Strip Connections

OVS - Override Switch

OS - Outdoor Sensor

OS - Outdoor Sensor

R - Low Voltage Hot

OVR - Override Hot

P2

L2

A1

L1

N

OR

A1

L1

L2

P2

N

CONNECTIONS

LINE VOLTAGE

(See Note 4)

VOLT

VOLT

(See Note 1)

P - Signal in from Utility Control Device (Peak Control)

OV4 - Relays #7, 8, and 9 Override/Multiple Control Input

208/240

120

E - Room Temperature Setback or Independent Relay Control (See Note 5)