SYSTEM SECURITY CODE

The default System Security Code is ‘828828’.

To change the System Security Code:

(a) Enter Programming and select Setup-Set-

tings-MBS-Change SSC.

(b) After selecting Change SSC, enter the new

password (min of 1 number, max of 6 numbers)

and confirm new password. Enter OK to ac-

cept or CANCEL to exit the window and can-

cel the new password. The password may be

changed again before exiting the programming

software without entering the new password.

(c) Once this password is changed, the pro-

gramming can only be accessed by the new

password or universal password which is

‘288288’.

(d) The MBS will allow 3 attempts to enter the

correct SSC password before closing the pro-

gramming.

DISTRIBUTOR PASSWORD

The default Distributor Password is ‘288288’.

The Distributor Password cannot be changed.

AUTHENTICATION PASSWORD

The default Authentication Password is

‘12345678’. To change the Authentication

Password:

(a) Enter Programming and select Setup-Set-

tings-MBS-Change AC.

(b) After selecting Change AC, enter the new

password (min 1 number, max 8 numbers) and

confirm new password. Enter OK to accept the

change or press CANCEL to exit the window

and cancel the new password.

(c) The universal password does not ap-

ply to the Authentication code. The entire

password must be reset. Refer to section

4.48.

GENERAL RULE

2.05 When viewing any programming

screens, the shaded items are informative

items and cannot be changed. The white items

are changeable items. In all screens, OK will

accept the change and CANCEL will exit the

window.

3.

SOFTWARE INSTALLATION

3.01 Programming of the Compass

can be done through the PC using a RS232

interface. The software is shipped with each

system and should be copied to the PC local

directory.

3.02 Before initializing the software pro-

gramming, connect the RS232 cable to the

Master Base Station PC setup port and also

to the COM port of the PC.

3.03 Run the setup program by executing the

file “PABXCFG.EXE”.

3.04 Check to see what COM port is being

used on the PC. If the correct COM port is not

selected in the programming, then select the

correct port and press OK to start the connec-

tion process again. When the COM port is

correct, the MBS version is then displayed.

3.05 Compass PC setup software port set-

tings default to COM 1 at a baud rate of 19200

bps. Compass software port settings

must match PC COM port settings. To

change settings, find the file named pbx-set.ini

and modify the port settings to 9600 bps

(needed for MBS).