4.4
Rear panel description
Alyseum
MS-812
More than Technology
+15V
-15V
COM
+12V
-12V
COM
EURO
FRAC
MADE IN EEC
COM
COM
COM
OR
8
FULL RANGE TRIM
10
9
PIN 1
8.
FRAC Power Connector, not available.
9.
IEC 60603-13 (DIN 41651) 10 pins – Power Connector for Eurorack version only.
10.
Position of the calibration trimmer behind the back panel
Always follow the rules and recommendations of the power supply manufacturer before
connecting the module.
4.5
Reference voltage tuning
For expert only, need hi-precision voltmeter (20.000 points)
A trimming potentiometer allows you to fine tune the voltage span of the analog converters.
To ease the setting, there is a dedicated calibration preset (see 5.1.1) that gives various reference
voltages on all CV outputs:
Connect on CV out 1, and turn the trim to adjust the voltage precisely to 10,666 Volts.
The other outputs are not used for calibration but rather to check that the module is OK at
manufacturing.