Alyseum, 4 rear panel description, 5 reference voltage tuning – Alyseum MS-812 User Manual

Page 7

Advertising
background image

MS-812 – User’s manual © - Revision 1.9

Page 7

4.4

Rear panel description

Alyseum

MS-812

More than Technology

+15V

-15V

COM

+12V

-12V

COM

EURO

FRAC

MADE IN EEC

COM
COM

COM

OR

8

FULL RANGE TRIM

10

9

PIN 1

8.

FRAC Power Connector, not available.

9.

IEC 60603-13 (DIN 41651) 10 pins – Power Connector for Eurorack version only.

10.

Position of the calibration trimmer behind the back panel

Always follow the rules and recommendations of the power supply manufacturer before

connecting the module.

4.5

Reference voltage tuning

For expert only, need hi-precision voltmeter (20.000 points)

A trimming potentiometer allows you to fine tune the voltage span of the analog converters.
To ease the setting, there is a dedicated calibration preset (see 5.1.1) that gives various reference
voltages on all CV outputs:
Connect on CV out 1, and turn the trim to adjust the voltage precisely to 10,666 Volts.
The other outputs are not used for calibration but rather to check that the module is OK at
manufacturing.

Advertising