EXPLANATION OF EACH CONTROL

The outputs from the CV and Gate channels are found in the box labeled ‘outputs’ on the
front panel.

CV CHANNELS

Oberkorn has three CV channels A, B and C. They are just about identical, except that C
does not have glide.

Each channel is completely independent form the others, though they will be clocked
together and be of the same sequence length.

So I will just explain one channel (A) and from there you will know what the others are doing.

CV Controls

Each channel has 16 CV controls. When a step is active, the voltage set by the control is
output at its socket.

LED

When a step is active, its LED will be on.

A-LEVEL Control

This is used to set the overall level of the CV signal output at the socket. It’s an attenuator.