35

AN-16/

i

i

Nput

M

odule

u

ser

G

uide

remaining three AN‑16/i Input Modules to ports B, C, and D.
On the Receive side

3.

Connect a Cat‑5e cable from port A on the second System

4.

Bridge to the A‑Net In jack on the first AN‑16/o Output

Module.
Repeat this process to connect ports B, C, and D to the

5.

remaining AN‑16/o Output Modules.
Connect the two sides of the system by running a Cat‑5e

6.

cable (with or without an EtherCon connector) between

the two A‑Net Bridge jacks on the System Bridges.

To use other configurations, simply move any pair of AN‑16/i and AN‑16/o

units.

In the following example, the devices connected to port D on the System

Bridge have been swapped to create a 48 x 16 system.

AN-16/i
AN-16/i
AN-16/i
AN-16/o

AN-16/o
AN-16/o
AN-16/o
AN-16/i

A-Net Out

A-Net In

A

B

C

D

A

B

C

D

Bridge

System Bridge

System Bridge

A 48 x 16 system is created by exchanging the units connected to port D on the

System Bridge.

Remember, the total cable length between A‑Net devices should not exceed

500 feet, 150 meters. Cables used to connect A‑Net devices to the System

Bridge are included in this calculation.

Configuration Notes

When configuring 64‑channel systems that send data in both directions,

Aviom suggests the following module combinations. While not mandatory,

these suggestions are made to accommodate the standard wiring practices

that Ethernet uses. (Aviom’s A‑Net technology is based on Ethernet.) Some

wire pairs in a standard Ethernet cable are not next to each other inside the

jacket of the cable. This can account for slightly higher data errors in rare

cases.

The configuration recommendations apply to systems configured as

16 x 48 and 32 x 32, not those sending data in only one direction. The module

combinations are applicable especially when using long cable runs.

For 16 x 48 (or 48 x 16) configurations, place the three similar modules

Advertising