Clip Indicators

Two red LEDs illuminate if the headroom has been exceeded. This can occur by driving a signal too hard into

the EQ, or by applying too much boost in any of the bands. Clip detectors are located at the output of the filter

stage. If clipping does occur, lower the input level feeding into the unit until the LEDs stop blinking.

High Pass and Low Pass Filters

The High Pass Filter is located on the lower left of the panel. The

HP

knob selects the corner frequency of the

24 dB-per-octave high pass filter. The range is from 30 Hz to 240 Hz in 4 steps. All signals above the selected

frequency are passed along to the next filter section and onto the outputs. This is the first filter that the signal

passes through.

The Low Pass Filter is located on the lower left of the panel. The

LP

knob selects the corner frequency of the

12 dB-per-octave low pass filter. The range is from 3 KHz to 12 KHz in 4 steps. All signals below the selected

frequency are passed along to the next filter section and onto the outputs. This is the second filter that the signal

passes through.

EQ 1/2

The

EQ 1/2

section occupies the space n the middle of the front panel. Each band of this reciprocal parametric

EQ has 3 controls (level, frequency, and bandwidth). The two knobs control level (EQ boost or cut) and frequency

respectively. The two buttons in the middle of each band alter the bandwidth of the filter. This can be changed

from 1/5th an octave at its narrowest, to 3 octaves at its widest. The EQ1 filter has a frequency range of 45 Hz to 1

kHz. The EQ2 filter has a frequency range of 650 Hz to 15 kHz. The gain range of each filter is +/- 15 dB. On the

right side of the filters you can find the bypass (EQ x in) buttons of each filter.