Checkline BLL User Manual

Page 3

Advertising
background image

Electromatic Equipment Co., Inc.

-14-

NOTES

Electromatic Equipment Co., Inc.

-3-

2.0

CALIBRATION CURVES


Calibration curves

Declaration

Measuring range

Wood chips

Standard wood chips

10 - 50%

Coarse chips

Coarse wood chips

10 - 50%

Industrial chips

Industrial wood chips

10 - 50%

Test block

! Only for testing the BLL with the test block !

Wood chips: standard chips of wood (forest wood chips) according to EU-norm

CEN/TS 14961 class P16 and P45.

Coarse chips: for coarse wood chips P45 but with fewer fines.

Industrial chips: for industrial chips of wood without barks and fines (similar

P63)


Definition of wood chips classes

The stated numbers refer to the particle size that goes through round gaps of the
corresponding diametres (e.g. P16: 16 mm).

o

P16

minimum 80% of the bulk is between 3,15 and 16 mm

o

P45

minimum 80% of the bulk is between 3,15 and 45 mm

o

P63

minimum 80% of the bulk is between 3,15 and 63 mm


Compression of wood chips

The BLL is calibrated for normally compressed wood chips. If the measured wood
chips are compressed to a much lesser or greater extent, this will cause measuring
imprecisions. Normally compressed wood chips are defined in norm CEN/TS 15103
(determination of the bulk density).



3.0

DETERMINATION OF THE MATERIAL REFERENCE MOISTURE



The principle is a comparison measurement with the dehydration method according
to CEN/TS 14774. Take the measured sample and weigh it. Dry it out in an oven
and weigh it again.






100

%

×

=

Mn

Mt

Mn

F

M

n

: Mass with average moisture content

M

t

: Mass of the dried sample

%F: Calculated moisture content

Advertising