Eration of the keyboard v. op – COP-USA AU40Z User Manual

Page 5

Advertising
background image

c)

Some of the ID-Code of the protocols are set as follows:

d)

Switching control between intelligent decoder and multiplexer.:

The keyboard can be operated

1 2 3 4 5 6 7 8

ON

MinKing A01/4800Bps

MinKing B01/9600Bps

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

PELCO-D/2400Bps

1 2 3 4 5 6 7 8

ON

PELCO-P/4800Bps

1 2 3 4 5 6 7 8

ON

PELCO-P/9600Bps

1 2 3 4 5 6 7 8

ON

Ultrak/9600Bps

1 2 3 4 5 6 7 8

ON

PANASONIC/9600Bps

in two modes: Intelligent Decoder and Multiplexer. When power supply is on it is operated on the
default mode of Intelligent Decoder. Press [F3] down until the LCD disply“CONTROLLING MULX” ,
then control the processor by the RS-232 output of the keyboard. Attention! If the LCD is not the right
state, the Multiplexer can not be under of control.

eration of the Keyboard

V. Op

ra /Decoder:[CAM]+[N]+[Enter]

1. Select Address of Speed Dome Came

Display: Current CamID:001

Description:N –– No. of camera from 0 to 255

controlled. When the value N is in conformity with the

2.

se

Function:Select the address of the camera to be

address of the speed dome, it will be under control.

To

t preset position:[PRESET]+[N]+[ Enter]

Display:Preset No:001

reset position from 1 to 128.

ion.

3.

Description:N –– No. of p

Function:Store current position and refer it as No. N posit

Call the Preset position:[CALL]+[N]+[ Enter]

Display:Call Number:001

et position from 1 to 128.

ition.

4.

Description::N –– No. of pres

Function: Transfer the camera to the position of No. N preset pos

Cancel the Preset position:[PRESET]+[N]+[OFF]

Display:Preset No:001

reset position from 1 to 128.

Description:N –– No. of p

Function:Delete the No. N Preset position stored.

Advertising