The prompt messages are displayed on both op and bottom lines and information of every pattern is displayed in

the middle of the screen. One line includes data of two patrol positions. Move the cursor by PAN LEFT/RIGHT

and change values by TILT UP/DOWN. Press down buttons for more than one second to speed up operation.

Press CLOSE button to exit the Edit state and store the revisions. The program can search the first position where

POS is “---”, and store data in front of it and regard data after it ineffective. Look the above drawing for example,

the program stores first four patrol positions. The settable range of POS is from 1 to 63 and 65 to 128. When POS

is “---“, it means the range of the patrol is finished. The settable range of SP is from 0 to 8 (0 is the same with 1

and has the fastest speed while 8 has the lowest speed). The settable range of TM is from 0 to 99 seconds.

Operation of Title of Preset Position under Edit State. After entering into Edit state, the display on the screen

is shown as follows: from the drawing we can find the current setup is the

first preset position with the title of “NO TITLE”. Move the cursor by PAN

LEFT/RIGHT and change values by TILT UP/DOWN. Press down buttons for

more than one second to speed up operation. Press CLOSE button to exit the

Edit state and store the revisions. The title of the preset position can include 8

characters in maximum such as 0-9, A-Z, +, - and blank. Note: the first letter

should be 0-9 or A-Z, otherwise it means the title of the preset position should be deleted. When calling the preset

position, it only displays “NO.XXX” without the title.

IV. Setup of the Intelligence Full-Dome Pan/Tilt

Before installing the product, first of all confirm the communication protocol and the baud rate of the main

machine in the system, then set the dip-switch SW2 of the pan/tilt to be identical with that of the system, set the

address of the pan/tilt on SW1 and the type of the communication protocol and the baud rate on SW2.

Dip-Switch of Address Dip-Switch of Protocol

(Figure 1)

1. Terminal Resistor

The jumper JP1 is the option switch of 120 Ω terminal resistor of the bus RS485. When it is at 2—3 state, 120
Ω terminal resistor is opened and no bus 485 is connected; when it is at 1—2 state, 120 Ω terminal resistor is

connected in parallel with the bus 485. In the bus RS485 system, there is only one pan/tilt, which has the terminal

NO – No.of Patrol Position
POS – No.of Preset Position
SP – Leaving Speed
TM – Dwell Time

SEQ:01 – It means current set sequence is 1
CLOSE:EXIT – Press CLOSE to exit Edit state

After entering into Edit state,following in-
formation displays on the screen:

EDIT AREA: one line includes data of two patrol positions.