9c. Simple spark-testers are readily available and

inexpensive. Thexton Part # 404 is available
from a variety of retailers, and similar units are
available form other manufacturers. See Figure
7.8.

9d. At operating speed, the ignition should produce

voltage approaching 12,000. See Figure 7.9.

9e. At pull-over speed (~ 600 RPM), voltage should

be at least 10,000V. See Figure 7.10.

NOTE: Flash-over voltage will vary with spark plug

condition and gap.

NOTE: Pull-over speed may vary from operator to

operator.

Figure 7.8

Instructions on
back of package

Figure 7.9

1 reticle = 4,000 Volts
waveform is
3 reticles tall

Figure 7.10

Pull-over speed: waveform is half-way

between 2nd and 3rd reticle (10,000 V.)