Stop switch – Cub Cadet MTD 90 Series User Manual

Page 88

Advertising
background image

78/83/90 Series Horizontal Shaft Engines

82

Stop switch

All MTD horizontal engines that are in use in North
America have a stop switch built into the throttle lever
assembly. MTD engines used on snow blowers have an
additional stop (ignition) switch in the engine shroud.

To test the stop switch (throttle):

1.

Remove the control panel by following the steps
described in Chapter 3: Air Intake Systems.

2.

Test the remote (ignition) stop switch first by follow-
ing the procedures described in the next section of
this chapter.

3.

Disconnect the lead that runs from the module to
the stop switch. See Figure 7.2.

NOTE: The blower housing was removed for picture

clarity.

4.

Connect one lead of a digital multimeter to the lead
going to the stop switch. Connect the other lead of
the digital multimeter to a good ground.

5.

Set the multimeter to the ohms (

Ω) scale.

6.

Operate the throttle lever while watching the multim-
eter.

When the throttle is all the way to the right (stop),
the multimeter should read at or near 0.0

Ω, indicat-

ing continuity. See Figure 7.3.

When the throttle is all the way to the left (full throt-
tle), the multimeter should not show continuity.
See Figure 7.4.

Figure 7.2

Disconnect switch

Figure 7.3

Switch lead

Throttle lever

continuity

Figure 7.4

no continuity