C&H Technologies M222 User Manual

Page 19

Advertising
background image

A-1

APPENDIX A: CONNECTORS


MAXIMUM

VOLTAGE/CURRENT:

The

maximum

voltage that may be applied to any connector on the M222 is
125 VDC, 141 VAC rms, or 200 VAC peak. These limits
apply only if the product is installed in a humidity-controlled
(<60% RH) environment where airborne contaminants and
transients are controlled, and there is NOT a relay
connection made to power mains. If these conditions
CANNOT be maintained, then the maximum voltage is 60
VDC, 43 VAC rms or 68 VAC peak.

The maximum current (non-inductive) that may be applied to
the M222 is:

Per Switch: 5 ADC, 5 AAC peak, 100W DC, 100VA AC
Per Module: 300W DC, 300VA AC



Pin # Use

Pin # Use

Pin# Use

1

CH0_NC

16

CH0_NC

31

CH0_NC

2

CH0_COM

17

CH0_COM

32

CH0_COM

3

CH0_NO

18

CH0_NO

33

CH0_NO

4

CH1_NC

19

NC

34

CH1_NC

5

CH1_COM

20

CH1_NC

35

CH1_COM

6

CH1_NO

21

CH1_COM

36

CH1_NO

7

NC

22

CH1_NO

37

CHGND

8

CH2_NC

23

CH2_NC

38

CH2_NC

9

CH2_COM

24

CH2_COM

39

CH2_COM

10

CH2_NO

25

CH2_NO

40

CH2_NO

11

CH3_NC

26

NC

41

CH3_NC

12

CH3_COM

27

CH3_NC

42

CH3_COM

13

CH3_NO

28

CH3_COM

43

CH3_NO

14

CHGND

29

CH3_NO

44

CHGND

15

CHGND

30

CHGND

NC = No Connection

Figure A-1. Front Panel I/O Signals

C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com