Appendices, 1 - maximal voltage range for global scaling – Eowave Eobody1 User Manual

Page 21

Advertising
background image

21

manual ©eowave/Ircam 2003

user’s manual

Appendix 1 / Maximal voltage range

Appendices

0

Analogue signals

3V

5V

1023

Dead areas

Digital
value

Reference
voltage

1 - Maximal Voltage Range for global scaling

The trimmer position enables to set the maximal analogue voltage before conversion to digi-
tal. It means that analogue signal from 0 to 5 Volts will be converted into digital values from
0 to 1024. Some sensors may have a range from 0 to 4 Volts. To get the maximal digital
range, the trimmer should be adjusted to 4 Volts. Note that voltage references value below
2.5V may increase sensitivity to noise.

5V

2,5V

1023

512

Range

Analogue
signal

Digital
value

t

0

Signal 1
Signal 2

When the Maximal Voltage Range is set under the maximal voltage from the sensor, the
signal may clip and some information may be lost. Always ensure that the reference voltage
is set to the maximum range of the connected sensors.

maximum range of the signals