Appendix 2 example of a sysex configuration, Type of information – Eowave Eobody1 User Manual

Page 22

Advertising
background image

22

Appendix 2 / SYSEX

user’s manual

manual ©eowave/Ircam 2003

2 - Example of a Sysex configuration of an

eo•body preset

The whole sysex file has to be sent at one time

To modify parameters, values from row 3 for the switches, from row 4 for the
potentiometers, from row 6 to 23 for imputs 1 to 16 need to be adjusted.

0,

‘eoprogram ‘;

program name

(for internal use of the editor only)

1,

240 0 32 57 64 127;

header tag

(not to be changed)

2,

0 8 0 0;

empty informations for further use

3,

1 0 1 0 1 0 2 0 1 0 3 0 1 0 4 0;

switch configuration

4,

1 0 5 0 1 0 6 0 1 0 7 0;

potentiometer configuration

5,

0 0;

empty informations for further use

(not to be changed)

6,

0 0 8 0 0 8 1 0 0 0 0 0 3 0 0 0 0 0;

input 1 configuration

7,

0 0 8 0 0 8 2 0 0 0 0 0 3 0 0 0 0 0;

input 2 configuration

8,

0 0 8 0 0 8 3 0 0 0 0 0 3 0 0 0 0 0;

input 3 configuration

9,

0 0 8 0 0 8 4 0 0 0 0 0 3 0 0 0 0 0;

input 4 configuration

10,

0 0 8 0 0 8 5 0 0 0 0 0 3 0 0 0 0 0;

input 5 configuration

11,

0 0 8 0 0 8 6 0 0 0 0 0 3 0 0 0 0 0;

input 6 configuration

12,

0 0 8 0 0 8 7 0 0 0 0 0 3 0 0 0 0 0;

input 7 configuration

13,

0 0 8 0 0 8 8 0 0 0 0 0 3 0 0 0 0 0;

input 8 configuration

14,

0 0 8 0 0 8 9 0 0 0 0 0 3 0 0 0 0 0;

input 9 configuration

15,

0 0 8 0 0 8 10 0 0 0 0 0 3 0 0 0 0 0;

input 10 configuration

16,

0 0 8 0 0 8 11 0 0 0 0 0 3 0 0 0 0 0;

input 11 configuration

17,

0 0 8 0 0 8 12 0 0 0 0 0 3 0 0 0 0 0;

input 12 configuration

18,

0 0 8 0 0 8 13 0 0 0 0 0 3 0 0 0 0 0;

input 13 configuration

19,

0 0 8 0 0 8 14 0 0 0 0 0 3 0 0 0 0 0;

input 14 configuration

20,

0 0 8 0 0 8 15 0 0 0 0 0 3 0 0 0 0 0;

input 15 configuration

21,

0 0 8 0 0 8 0 1 0 0 0 0 3 0 0 0 0 0;

input 16 configuration

22,

247;

Footer tag

(not to be changed)

Switches and potentiometers use the same parameters

Switch configuration 4 x 2 bytes for switches A, B, C, D
Potentiometer configuration 3 x 2 bytes for potentiometers 1, 2, 3
channel C (0-15, type of information X (0-5), value 0 0 (0-127, in 8 bits on 2 bytes)
C X 0 0

Example:

Controller 1 on Channel 1:

0 0 1 0

Controller 64 on Channel 16: 15 0 0 4

Type of information

0

CC

1

Note On Trigger

2

Program Change

3

Picht Bend

4

Polyphonic After Touch

5

Monophonic After Touch

An entire sequence for pots will be

Example CC 1 to 3 on Channel 1
4, 0 0 1 0 0 0 2 0 0 0 3 0;

Advertising