MOUNTING AND WIRING THE SAFETY
REVERSING SENSORS

Mounting:

1. Slide a 1/4"-20x1/2" carriage bolt head into the slot

on each sensor. Use wing nuts to fasten sensors
to brackets, with lenses pointing toward each other
across the door. Be sure the lens is not obstructed by a
bracket extension (Figure 5).

2. Finger tighten the wing nuts.

Option A - Installation Without Pre-Wiring:

1. Run the bell wire from both sensors to the garage

door opener. Attach the wire to the wall and ceiling
with the staples (Figure 6).

Option B - Pre-Wired Installation:

If your garage already has wires installed for the safety
reversing sensors, follow the instructions below:

1. Cut the end of the safety reversing sensor wire, making

sure there is enough wire to reach the pre-installed
wires from the wall (Figure 7).

2. Separate the safety reversing sensor wires and strip

7/16" (11 mm) of insulation from each end. Choose two
of the pre-installed wires and strip 7/16" (11 mm) of
insulation from each end. Make sure that you choose
the same color pre-installed wires for each sensor
(Figure 8).

3. Connect the pre-installed wires to the sensor wires with

wire nuts making sure the colors correspond for each
sensor (Figure 9).

Figure 5

Figure 6

Figure 7

Figure 9

Figure 8

Safety
Reversing
Sensor
Wires

White

White/Black

Not Provided

Pre-Installed Wires

Pre-Installed

Wires

7/16"

(11 mm)

7/16"

(11 mm)

Safety Reversing
Sensor Wires

Wing Nut

1/4"-20

Carriage Bolt

1/4"-20x1/2"

Lens

Advertising