5

„

Detection Settings

*1 Press the

button to set between the range of

 and (ms).

*2 Press the

button to set the retouch sensitivity to a range of between

.'W and .'W

and set the warning output level to a range of between

12 and 2.

*3 Press the

button to toggle between

Q((/Q0/-''2.

*4 Can be set between the range of

 and .

*5 Can be set between the range of

 and .

*6 Can be used only for the types with the external input.

Note that these functions can be used via communication when connecting with the network
unit NU Series.

*7 Only monitor output types (FS-N11MN).

„

Display Settings

*1 Press the

button to toggle between

5VF/2`2A/D`DA/2AD`/2`DA

*2 Press the

button to set between the range of

2 and 2.

„

System Settings

*1 Main unit only.

„

Two Output

*2

*1 Press the

button to set between the range of

 and (ms).

*2 Only 2 output types (FS-N13N/N13P/N14N/N14P/N13CP/N14CP).

Normal (light intensity)
detection mode

DATUM1 mode *

2

Timer OFF

Off-delay timer *

1

On-delay timer *

1

One-shot timer *

1

DATUM2 mode *

2

Area detection mode

Rising Edge Detection Mode

Falling Edge Detection Mode

Settings complete

Go to display setup mode

Go to system setup mode

Return to original
detection setup mode

External input off

External calibration input

Preset input

Zero shift input

Reset input

Light transmission OFF input

Pause mode transition input *

3

Sleep mode transition input

Light emission power selection *

4

Analog scaling *

5

Return to normal display

*6

*7

MODE

MODE

MODE

Normal display method

Reverse display

Settings complete

Go to system setup mode

Go to detection setup mode

Return to original display setup mode

Sub-display off

Extended display

Bar display

Excess gain display

Light intensity hold display *

1

Excess gain hold display *

1

L-on / D-on display

Disable the saturation of the
Preset function

Enable the saturation of the
Preset function *

2

Return to normal display

MODE

MODE

Disable APC

Enable APC

Settings complete

Go to detection setup mode

Go to original display setup mode

Return to system setup mode

Normal operation

Twice the number of
interference-prevention units as

56&

(response time 2 times slower)

Eco feature off

Enable eco feature

Reduce power consumption
(response time 4 times slower)

Disable common key operations

Enable common key operations

Standard current value display

Maximum current value display
(4 times hysteresis)

Return to normal display

*1

Light intensity detection mode

Limit setting output mode

Auto reset

User reset

Warning output mode

Timer OFF

Off-delay timer *

1

On-delay timer *

1

One-shot timer *

1

Settings complete

Return to normal display

MODE