PROBLEM

POSSIBLE CAUSE

REMEDY/REFERENCE

Steamer not level

See note #2.


Hot Water to con denser

See note #2.


Reduced steam flow into cooking

Steam generator scale buildup.

Descale steam generator with approved

Compartment.

Descaler


Steam nozzle scale buildup.

See note #1.


Steam solenoids scale buildup

See note #1.


Electric models only

See note #4.

Voltage too low for unit.


Electric models only

See note #1.

Faulty heating element or controls.


Steam flow does not stop when

Operating in manual mode.

Switch to timed mode for timer to be

timer stops.

Effective.


Stuck open steam valve

See note #1.


Inoperative five controls inside

Turn off electricity at main disconnect

Cabinet.

switch. See note #1.


Water leaking from bottom of

broken or loose plumbing inside

Turn off electricity at main disconnects

Cabinet.

steamer cabinet.

switch and close water supply valve(s).

See note #1.


Water leaking from water pipes

Plumbing needs repair

See note #3.

or drain lines.

Food takes too long to cook.

Not enough steam movement in

Make proper connections. Refer to Service

(Cook in perforated pans when

compartment. Hot water con-

Manual.

possible.)

Connected to condenser line.


Pans too close to the bottom of

Put pans in racks near top of cabinet.

cabinet.


Steam generator scale buildup.

Descale steam generator with USDA

approved descaler


Compartment overloaded with

Put less food in pan. Use fewer pans.

too much food.


Voltage too low for unit.

See note #4.

Suggested cooking times are

Extend cooking times for altitudes above

usually listed for cooking at sea Level

2500 FEET.



Compartment bottom dirty with

Juices and /or food leaking from

Put a solid pan under perforated pans to

food drippings.

pans.

catch drippings, or put less food in pan.


TROUBLESHOOTING NOTES

1. If problem is inside the steamer, call an authorized
Service representative Cleveland Range will not pay for
Non- warranty repair centers.
2. Proper installation of the Convection Steamer
Responsibility of the owner or installer Refer to Cleveland

3.

Repair to external wiring should be done by a Licensed
Electrician.

4.

For more information on products and services, contact
your nearest Authorized Service Representative.