Common key-operations function, Sensitivity, Common key-operations function -32 sensitivity -32 – KEYENCE LV-N10 Series User Manual

Page 80

Advertising
background image

4-5 System Settings (SYS)

4

Set

tings
for Ad

van
c

ed Fu

nct
ion
s

4-32

- Digital Laser Sensor LV-N10 Series User's Manual -

Some operations on the main unit are applied equally and simultaneously to all
expansion units connected to it.

The operations that can be applied to all expansion units are as follows:

• Enabling/disabling the preset function

"Preset Function" (page 3-6)

• Enabling/disabling the zero shift function

"Zero Shift Function" (page 3-17)

• Enabling/Disabling the key lock function

"Key Lock" (page 3-23)

This function is effective only with the main unit to which expansion units
are connected. This function cannot be used with an independent main unit
or with the expansion units.

When set to rESo, the hysteresis during detection will decrease. This is useful for
detecting workpieces with little received light intensity difference such as when
detecting a transparent workpiece with a retro-reflective model.

Note that when the sensitivity is set to rESo and the hysteresis drops,
any cause of received light intensity variation such as vibration could
result in malfunction.

Common Key-Operations Function

Refer to page 4-2 "System Settings (SYS)" for setting methods.

Display

Function

oFF (OFF)

Disables common key operations. (Default)

on (ON)

Enables common key operations.

Reference

Sensitivity

Refer to page 4-2 "System Settings (SYS)" for setting methods.

Display

Function

Std (Standard)

Standard (Default)

rESo (Reso)

High resolution

Point

Advertising