background image

4-6 2-output Settings (

)

4

Set

tings
for Ad

van
c

ed Fu

nct
ion
s

4-35

- Digital Laser Sensor LV-N10 Series User's Manual -

Warning output mode

If output 2 is set to "ALrt" (warning output mode), output 2 turns on (or off if the output
condition is set to N.C.) when either of the following errors occur:

• Correction error in DATUM1 or DATUM 2 mode
• ErH

For error recovery procedures, see

"Troubleshooting" (page 6-2).

Counter output mode

When output 2 is set to [Cnt (counter output mode)], detection which counts the
output-1 output (OFF

J ON edge) up to 9999 and makes a comparative judgment

with the setting value is possible.
The following 3 types of counter functions are available.

* When the counter value reaches 9999 (maximum value), 9999 is held thereafter.

Refer to page 4-3 "2-Output Settings (

)" for setting methods.

Reference

Refer to page 4-3 "2-Output Settings (

)" for setting methods.

Display

Function in brief

oUr1

(Over1)

Over counter 1
Turns ON at a value higher than the setting. The count con-

tinues until reset.

*

oUr2

(Over2)

Over counter 2
The output turns ON only when the value is the same as the

setting value. The count continues until reset.

*

Auto

(Auto)

Auto reset
Outputs one-shot when the value is the same as the setting
value. The count value is automatically reset. The one-shot
time (Shot) can be set within the range of 1 to 9999 (ms).
Default: 10 ms