Selecting an operating mode of the dl-cl1, Selecting an operating mode of the dl-cl1 -3, 1 cc-link communication and operating modes – KEYENCE DL-CL1 User Manual

Page 31: Comm u nic a ti ng w it h th e sk-1 000 se ri es

Advertising
background image

3-1 CC-Link Communication and Operating Modes

3-3

3

Comm

u

nic
a

ti

ng

w

it

h th

e

SK-1

000 Se

ri

es

- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -

Select an operating mode of the DL-CL1 to suit the functions of the sensor amplifiers
to be used.
The specific CC-Link device configuration and the data that can be communicated
using cyclic transfer vary with each operating mode of the DL-CL1. An appropriate
operating mode should be determined by considering the number of link points the
data that can be communicated.

"Configuring the Data Link" (page 2-10)

Yes: Available with sensor amplifiers of ID 01 to 08. No: Not available.
*1

For details of the functions assigned for motions commands and setting/status read/write,

see

"Device Maps" (page 3-4) and

"Command Parameter List" (page 3-26).

*2

In remote register RWw, specify the ID number of the sensor amplifier from which to read.

*3

To use this communication method, create a program that controls commands by handshaking
between a remote input/output and remote register.

Selecting an Operating Mode of the DL-CL1

Method of

communication

with the master

station

Available function

of sensor

amplifier

*1

Operating mode of DL-CL1

Reference

page for

communication

method

Small-

memory

mode 1

Small-

memory

mode 2

Monitor

mode 1

Monitor

mode 2

Full

mode 1

Full

mode 2

1-station,

1x

2-station,

1x

4-station,

1x

1-station,

8x

4-station,

2x

2-station,

8x

page 3-4

page 3-12

Remote input RX

Read out-
puts 1 - 5

HI

Yes

Yes

Yes

Yes

Yes

Yes

3-4

LO

No

Yes

Yes

Yes

Yes

Yes

GO

No

Yes

Yes

Yes

Yes

Yes

Alarm
output

No

No

Yes

Yes

Yes

Yes

Not
used

Remote register RWr

Read judgment
value (P.V. value)

No

No

Yes

*2

Yes

Yes

Yes

3-7

Remote output RY

External
inputs 1-5

External
input 1

Yes

Yes

Yes

Yes

Yes

Yes

3-14

External
input 2

No

Yes

Yes

Yes

Yes

Yes

External
input 3

No

Yes

Yes

Yes

Yes

Yes

External
input 4

No

No

Yes

Yes

Yes

Yes

Not
used

Remote register
RWw

Change BANK number

No

No

Yes

Yes

Yes

Yes

3-17

Rewrite setting
value

No

No

No

No

Yes

Yes

3-17

Handshake control

program

*3

(Command commu-
nication)

Motion command

No

No

Yes

Yes

Yes

Yes

3-22

Read output

No

No

Yes

Yes

Yes

Yes

3-18

Read judgment
value (P.V. value)

Read external input
status

Read BANK number

Read setting/status

Write setting/status