- IV Series User’s Manual (Field Network) -

Cyclic communication setting method

When setting by IV-Navigator (IV-H1)

Set the field network settings of the sensor to
[EtherNet/IP].

1

Display the Advanced Sensor Settings

screen.

2

Select the [Environmental] tab, and then

click the [Setting] button under [Field

network].

3

Select [EtherNet/IP] in [Protocol] for the

field network.

To enable the handshake control, check this
check box .

y

When the protocol is set as [Disable],

this setting item is shaded and cannot be

selected.

y

When the data handshake control is set as

[Enabled], the status result will not be updated

until [Result acquisition complete notice]

(“Address2, Bit0” Output Assembly) is input.

“Operating procedure of the cyclic

communication” (Page 3-26)

4

After the setting is completed, click the

[OK] button.

The system returns to the main screen in
[Program].

5

Click the [OK] button.